6 November 2006
BD X-Monitor (Pyro & Boost Only)
12
If the "PYRO" reading on the display is showing "----" then there is a short circuit with
the thermocouple or the wiring. If the display is showing "2213" then the module is
not showing the connection to the thermocouple or the thermocouple is faulty.
If the "TURBO" reading on the display stays at "0" then the module is not reading
any boost pressure.
The X-Monitor is calibrated to the thermocouple that is supplied with the kit and will
not register accurately if an existing or different thermocouple is used.
Analog signals are naturally affected by RF (radio frequency) noise. To eliminate
any possible chance of an erratic signal please choose a clean ground signal for the
X Monitor, that is clearly mounted away from the alternator wires or any other
voltage sources (positive battery cables, etc.). If for some reason you still have
erratic sensor readings try a direct ground connection to the battery.
Thermocouple wires should also be clear from any RF noise sources as well (i.e.
alternator, positive battery cables, etc). If the thermocouple signal is erratic then the
copper ground wire that is contained inside of the thermocouple wire can be
connected to ground to reduce a small amount of noise. Be sure to connect only
one end of this copper wire to eliminate any ground loops from forming.
If you have any problems or need replacement parts, call us at 1-800-887-5030,
between 8:30am and 4:30pm Pacific Time.