Bosch Evolution HDS7052U Руководство по конверсии - Страница 3
Просмотреть онлайн или скачать pdf Руководство по конверсии для Печь Bosch Evolution HDS7052U. Bosch Evolution HDS7052U 32 страницы. Dual fual ranges
Также для Bosch Evolution HDS7052U: Руководство по установке (36 страниц)
Safety
IMPORTANT SAFETY INSTRUCTIONS
Important Safety Instruc-
tions
•
Please read Installation Instructions before beginning the conversion
•
Please read all instructions before proceeding. Save the natural gas parts for
possible conversion from LP back to natural gas in the future
•
This kit is used to convert dual fuel ranges and gas ranges from natural gas
operation to propane (LP) gas operation. Only ranges manufactured by BSH
Home Appliances can be converted using this kit.
•
CAUTION: When connecting the unit to the propane gas,make certain the
propane gas tank is equipped with its own high pressure regulator. In addi-
tion, the range has its own pressure regulator. Verfiy that it is installed for the
appropriate gas supply.
•
The maximum gas pressure to this appliance is not to exceed 14.0 inches
water column from the propane gas tank regulator.
•
The following must be met when testing supply piping system:
a) The appliance and its individual shut-off valve must be disconnected from
the gas supply piping system at test pressures in excess of 1/2 psig (3.5
kPa).
b) The appliance must be isolated from the gas supply piping system by
closing its individual manual shut-off valve during any pressure testing of
the gas supply piping system at test pressures equal to or less than 1/2
psig (3.5 kPa).
•
WARNING: This conversion kit shall be installed by a qualified service
agency in accordance with the manufacturer's instructions and all applicable
codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage, personal injury or loss
of life. The qualified service agency is responsible for the proper installation of
this kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer's instructions
supplied with the kit.
•
For Massachusetts Installations:
1) Installation must be performed by a qualified or licensed contractor,
plumber or gas fitter qualified or licensed by the state, province or region
where this appliance is being installed.
2) Shut-off valve must be a "T" handle gas cock.
3) Flexible gas connector must not be longer than 36 inches.
•
High Altitude Installation Note: This range is CSA certified for safe operation
up to an altitude of 10,000 ft. without any modifications (except LP conver-
sion, when applicable).
English 1