Pre-Installation Requirements
10
Tools and materials
needed for installation:
Adjustable
pliers
Pipe wrench
for gas
supply
4 inch, rigid metal or
semi-rigid metal exhaust duct work
4 in.
(10.2 cm)
shutoff valve
clamp
(gas dryer)
ASSEMBLY HOSE
KIT - P/N 5304495002,
for steam models only,
is not included and
must be purchased
separately.
WARNING
• Failure to follow safety warnings
exactly could result in serious injury,
death, or property damage.
• DO NOT install a booster fan in
dryer exhaust duct.
• Install all clothes dryers in
accordance with the installation
instructions in this manual.
Phillips,
straight, &
square bit
screwdrivers
or
LP-resistant
Carpenter's
thread tape
level
(for natural
gas or
LP supply)
3-wire or 4-wire
240 volt cord kit
(electric dryer)
½" NPT
Gas line
union flare
adapters (x2)
and flexible
gas supply line
(gas dryer)
FIRE HAZARD
Electrical system
requirements
Because of potentially inconsistent
voltage capabilities, the use of this dryer
with power created by gas powered
Adjustable
wrench
generators, solar powered generators,
wind powered generators or any other
generator other than the local utility
company is not recommended.
or
Electrical requirements for
electric dryer:
External
CIRCUIT - Individual 30 amp. branch circuit
vent hood
fused with 30 amp. time delay fuses or
circuit breakers. Use separately fused
circuits for washer and dryer. DO NOT
operate washer and dryer on same circuit.
POWER SUPPLY - 3-wire or 4-wire,
120/240 volt, single phase, 60 Hz,
Alternating Current.
Metal foil
A 120/208 volt, single phase, 60 Hz,
tape (not
Alternating Current supply may be used on
duct tape)
dryers marked for use on rating plate.
Dryer is internally grounded to neutral
unless it was manufactured for sale in
Canada.
Only a 4-conductor cord shall be used
when the appliance is installed in a
location where grounding through the
neutral conductor is prohibited. Grounding
through the neutral link is prohibited for: (1)
new branch circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4)
areas where local codes DO NOT permit
grounding through the neutral.
NOTE
NOTE
IMPORTANT