AirStage UTY-RNK Series Руководство по эксплуатации - Страница 9

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Пульт дистанционного управления AirStage UTY-RNK Series. AirStage UTY-RNK Series 13 страниц. Air conditioner remote controller wired type

TEMPERATURE SET BACK TIMER

Instructions related to heating are applicable to "HEAT PUMP MODELS" and "HEAT RECOVERY MODELS" only.
The timer function is not available depending on the model.
To set the temperature SET BACK timer
1
Press the SET BACK button to change to the SET BACK confirmation display.
The SET BACK operating time and the set temperature will be displayed.
3
● Day setting
1
3
4
Follow steps
and
in "To set the WEEKLY timer" (p. 5). The TIMER DELETE button is also used as described in the
procedures for the weekly timer.
4
● Temperature setting
SET BACK
ON
temperature
24°C
Normal
temperature
To start/cancel the temperature SET BACK timer operation
● To start
ex. Display during SET BACK timer operation
(The operating time will not be displayed.)
Press the SET BACK button. The SET BACK confirmation
display appears for 5 seconds, and then the timer starts au-
tomatically.
NOTES
(1) The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner operation.
(2) The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be used.
(3) The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.
(4) During the COOL/DRY mode, the air conditioner will operate at a minimum of 18 °C even if the SET BACK temperature
is set to 17 °C or lower.
(5) The SET BACK operating time is displayed only in the SET BACK confirmation display. (Refer to step 1 for the SET
BACK confirmation display.)
(6) Room temperatures as low as 10, 12, and 14 °C cannot be set depending on the model.
● Operating time setting
2
3
Press the SET TEMPERATURE buttons to
set the temperature (from 10 °C to 30 °C).
ex. Operating time 15:00–22:00
OFF
28°C
24°C
If there is no existing
SET BACK tempera-
ture setting, "- -" will
be displayed for the
temperature.
SU MO TU WE TH FR SA
3 6 9 12 15 18 21
4
ex. When setting all days together
● To cancel
1
Press the SET BACK button, and then press the TIMER DE-
LETE button while the SET BACK confirmation display is
displayed. Even if the SET BACK button is pressed again,
the SET BACK timer will be cancelled.
2
Press the TIMER SET button
for 2 seconds or more.
5
3
4
Repeat steps
and
.
Press the TIMER SET button
for 2 seconds or more to
complete the temperature
SET BACK timer settings.
2
En-8