Adjusting the thermostat knob to the left backstop does not mean permanent shutoff
of the heating element. When the heater is in use without blocking the daily rate, we do not
recommend the temperature to be set above 55°C. Select the "OPTIMUM" symbol
as the maximum.
4 IMPORTANT NOTICES
4.1 INSTALLATION REGULATIONS
Without a confirmation of performed electrical installation issued by an authorised company,
-
the warranty certificate shall be void.
Check and exchange the Mg anode regularly.
-
Please make sure that for the connection of your heater you don't need an approval of the local
-
electricity supplier.
No stop valves can be put between the heater and the safety valve.
-
With overpressure in the water distribution system higher than 0.48 MPa, it is recommended
-
that a reduction valve is fitted before the safety valve.
All hot water outputs must have a combination faucet.
-
It is not allowed to handle the thermostat, aside from temperature resetting with a control button.
-
All electric installation handling, adjustment and replacement of the regulation elements shall only
-
be performed by an authorised service company.
The thermal fuse must not be turned off! In case of thermostat defect, the thermal fuse interrupts
-
electric power input to the heating element if the water temperature in the heater exceeds 90 °C.
If you don't use the heater (hot water tank) for longer than 24 hours, or if the facility with heater
-
is unattended, close the cold water inlet to the heater. Empty the heater if there is a risk of frost.
The heater may only be used in accordance with the conditions specified on the nameplate
-
and the instructions contained in this manual.
The recommended operating pressure in the hot water circuit is 0.48 MPa. At the hot water discharge
-
we recommend that a reverse flap and an expansion tank are installed (at least 4% of hot water
volume in the manifold) to eliminate reverse pressure shocks.
Both the electric and water installation must follow and meet the requirements and regulations
relevant in the country of use!
4.2 TRANSPORT & STORAGE INSTRUCTIONS
The device shall be transported and stored in dry place and protected from weather effects with temperature
range from -15 to +50°C. During loading and unloading the instructions stated on the packaging
shall be observed.