Alentec & Orion 24700 Руководство пользователя - Страница 8
Просмотреть онлайн или скачать pdf Руководство пользователя для Измерительные приборы Alentec & Orion 24700. Alentec & Orion 24700 8 страниц. Hose-end meter, standard
Manual 24700GBM_ARC6
7. Technical specification
Type:
Pickup system:
Materials:
Output:
Data storage:
Power supply:
Fluid connections:
Pressure:
Flow range:
Viscosity range:
Accuracy:
Weight:
Oval gears on steel shafts in a casted metal chamber with pressure drain grooves.
4 pieces of permanent magnets on one of the gears configured North-South-North-South to eliminate
magnetic history. The rotation is detected through the measuring chamber lid by a REED-switch on the
electronic printed circuit board eliminating the risk for shaft leakage.
Measuring chamber = Zinc, Handle frame/Valve housing = Aluminium, Gears = Vectra®, Casing =
Fibreglass reinforced Delrin®, Gear shafts = stainless steel, Overlay = Polycarbonate with 3M
adhesive, Valve spindle = Brass and Nitrile O-rings.
The meter complies with the RoHS directive.
LCD display with 4 figures and 1 decimal (XXXX.X), battery check symbol, Trip, Total and Unit.
Static E2RAM for set-up, Trip counter and Total counter
2 pieces of 1.5V standard battery, IEC LR03 / ANSI AAA
Inlet female G1/2 with O-ring groove and inlet strainer.
Outlet male G1/2 with an inside 60° cone.
Max working pressure = 5MPa (50 bar).
Min burst pressure = 15MPa (150 bar)
Normal = 1.5 to 15 L/min.
Possible = 0.5 to 25 L/min (Dependant of fluid)
8-2000 cSt.
From stock and normal fluids better than +/- 1%. After calibration within 5cl.
0.5 kg
8(8)