Formula Air RVA4-NX-06 Руководство по техническому обслуживанию - Страница 8
Просмотреть онлайн или скачать pdf Руководство по техническому обслуживанию для Блок управления Formula Air RVA4-NX-06. Formula Air RVA4-NX-06 14 страниц. Rotary valves
Step 3 : Introduce the new rubber blades into the metal vane gap. Make sure that the holes are aligned, and the flap
is in the right direction then bolt them back.
3.5
Noise level
The noise ratio of the component in our scope of supply in connected condition and without media is below 70 dB (A)
measured at 1 meter from the component.
Noise from transported media is not included.
IMPORTANT!
A higher noise level may occur depending on local conditions, transported material and other components connected
to the rotary valve. In this case separate measurements may be required.
If the total noise level in the area exceeds 85 dB (A), hearing protection must be used.
4. Components and spare parts
8
User manual | RVA Rotary valves
www.formula-air. com
Figure 8. Exploded view