8.4.2 Clearance under the modules
■
Minimum clearance
NOTE
• Rooftop or freefield mounting
Ensure a clearance of at least 4 cm between the rear
edge of the frame and the mounting surface (e.g. the
roof tiles) for the rear ventilation ofthe aleo module.
• Roof-integrated mounting
Ensure an appropriate interval, for example, to the
trough of the mounting system. Also ensure ade-
quate ridge ventilation, for example, with a roof
ridge ventilator.
■
Maximum clearance
NOTE
• The largest permissible clearance is defined by
national standards. This is used to design the instal
lation on the assumed effects of wind and suction.
• The actual maximum clearance of an installation is
determined by the sub-structure. Ensure that your
sub-structure adheres to the permissible clearances.
8.5
Avoiding seals
NOTE
• Avoid the use of a seal between aleo modules and
their mounting surface.
• Dry and cool operation can have a positive effect on
the performance as well as the service life of an
aleo module.
• Also for roof-integrated mounting, ensure good rear
ventilation to minimise loss of output which results
from a higher module temperature. Ensure adequa-
te ridge ventilation, for example, with a roof ridge
ventilator.
8.6
Clearance under the modules
NOTE
• Keep the space behind the laminate free of any
objects. This prevents damage to the insulating
back sheet and the junction box.
• Ensure that sharp or conductive parts (e.g. screws
or nails) do not protrude into the space behind the
module.
• If possible, take measures to prevent foreign ob-
jects (e.g. snow, ice, leaves, twigs, branches) from
being able to get behind the module.
Page 8/19
9 Electrical installation
9.1 Connectors
WARNING!
Incompatible or unsuitable connectors can
overheat. Fire hazard!
• Only use connectors that are the same type and
from the same manufacturer.
• Avoid using different types of connectors or ones
from different manufacturers, even :
- if connecting is possible
- if the connectors have the same basic designation
(e.g. "MC4") or
- if they are designated as "compatible".
_______________________________________________
You can find more details on this in the next two sections.
9.1.1 Module connectors
The various module types can be fitted with the following
connectors:
• Original Multicontact
• PV-JM601 (with locking)
You can find the specific connectors in the module data
sheet.
9.1.2 Connector peculiarities
NOTE
• Original Multicontact® MC4 connectors
• Only plug original Multicontact
connectors into original Multicontact
connectors.1
• PV-JM601 connectors
• Only plug PV-JM601 connectors into PV-JM601
connectors.
9.1.3 Replacing the connectors
You can remove the connector on a module and replace it
with another connector, if necessary. You retain the manu-
facturing warranty if you remove and mount with approved
tools in the proper way and according to the connector
manufacturer's instructions.
1
The original Multicontact® MC4 connectors are referred to as "MC4" in the data sheet.
aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany | [email protected]
MC4 (with locking)
®
MC4
®
®
Quick Reference Manual Rel. 4.2, 08/2015, en-GB-DE (1)