6B. WIRING AND SET-UP – ALTERNATIVE EXTERNAL CONTROL
Alternatively, use any other humidity control system as long as it has a dry contact, normally open output dedicated to controlling the dehumidifier.
Reference the installation literature provided with the alternative control for wiring, set-up, and operating details.
TO INSTALL AND USE AN ALTERNATIVE EXTERNAL CONTROL,
COMPLETE ALL STEPS:
1. Unplug the dehumidifier or turn off power to the circuit at the
breaker or fuse.
2. Run thermostat cable (use 18-22 AWG wire) from the alternative
external control to the control of the dehumidifier.
3. Trim about 1/4" of insulation from the end of the wires on
each end. Insert the wire into the terminals as shown in the
ALTERNATIVE EXTERNAL CONTROL WIRING diagram below.
4. Restore dehumidifier power.
ALTERNATIVE EXTERNAL CONTROL WIRING
7. CODES
(LOCATED ON BACK OF WIRE ACCESS COVER)
See the Installation Instructions for troubleshooting error codes. For additional
assistance, Technical Support is available Monday through Friday, 7:00 a.m. to
5:00 p.m. CST, at (800) 972-3710.
Contact Technical Support before replacing the unit or components and for
additional troubleshooting.
B2208490B • 10013947 • 1.22
© 2022 Anden | anden.com | 800.972.3710
Anden reserves the right to change specifications without notice.
EXTERNAL
CONTROL
TO SET THE DEHUMIDIFIER TO USE THE ALTERNATIVE CONTROL,
COMPLETE ALL STEPS:
1. With power to the dehumidifier, use the ON/OFF button to set the
dehumidifier to the OFF position.
NOTE: If the display backlight is not on, the first button press (any
button) will only turn the backlight on. Press the button a second
time to achieve the desired function.
2. Hold the MODE button on the on-board control for 3 seconds to
enter the Installer Set-up Menu.
3. Press MODE again and the display should change to EXTERNAL in
the center, and DISABLED on the right. Use the UP or DOWN arrow
buttons to set this to ENABLED.
4. Once the display reads EXTERNAL ENABLED, press the MODE
button to cycle through the other settings until the display blinks
DONE for 3 seconds.
5. Use the ON/OFF button to turn the dehumidifier ON. The display
on your unit should read EXTERNAL. Even if there is a demand for
dehumidification according to your external control, the dehumidifier
90-2542
will wait 3 minutes before turning on for the first time only.
ERROR CODE
E1
E3
E4
E5
E6
E7
E8
90-1854
FAILURE MODE
Internal %RH/Temperature Sensor Failure
Model A77 Remote Control Communication Loss
Insufficient Capacity
High Temperature Thermistor Failure
Low Temperature Thermistor Failure
Float Switch Open
Inlet Air Temperature Out of Range
4