ATI Technologies B12-69 Руководство по эксплуатации и ремонту - Страница 4

Просмотреть онлайн или скачать pdf Руководство по эксплуатации и ремонту для Передатчик ATI Technologies B12-69. ATI Technologies B12-69 20 страниц. 2-wire wet oxidant gas transmitter

Model B12-69 Wet Oxidant Gas Transmitter
The Series B12-69 is a two-wire transmitter system designed for use with a special oxidant gas
sensor (for Cl
, Br
, O
or ClO
3
2
2
of monitoring chlorine gas in applications where excessive moisture causes rapid blinding of standard
oxidant gas sensors.
Transmitters are housed in a NEMA-4X polystyrene enclosure (Figure 3) suitable for installation
in virtually any environment. The sensor cable is wired to the proper terminals in the transmitter through
the Pg 11 cable gland located in one of the enclosure knockouts. One cable gland and one ½" conduit
hub is supplied for customer installation. An optional LCD provides local indication of gas concentration
on the front of the enclosure. The display is supplied only when specified on the order, and cannot be
added in the field.
B12 Transmitters are also available in an explosion-proof version. The explosion-proof version is
housed in a galvanized steel enclosure (Figure 4) rated for Class 1, Div. 1, Groups B, C, & D locations.
LCD is not available on the XP version.
Figure 1 shows a typical insertion B12-69 gas monitoring system. The sensor is shown threaded
into a blind flange of a vent stack.
Figure 1 - Typical Insertion System Installation (ATI-0274)
O & M Manual
Rev-G, 7/15

INTRODUCTION

) suitable for use in very wet environments. It provides a low power method
2
- 4 -