Aleo P19 Краткое справочное руководство - Страница 12

Просмотреть онлайн или скачать pdf Краткое справочное руководство для Робототехника Aleo P19. Aleo P19 20 страниц.

10.6.2 Permissible loads for modules with standard frames
35mm
Load level
Permissible
pressure
Load level I
2400 Pa
Load level III
5400 Pa
10.6.3. Permissible loads for modules with Solrif
Load level
Permissible
pressure
Load level I
2400 Pa
Load level II
3900 Pa
Load level III
5400 Pa
10.6.4 Snow Load
If there is a risk of sliding snow, for load level II and III
depending on mounting type (chapter 10.8), an appropriate
measure has to be taken so that PV module frames on lo-
wer edge of PV modules will not be damaged (e.g. by using
snow hook)

10.7 Key to symbols

Symbol
Explanation
Permissible clamping area (criss-
GID AS034a
crossed, red)
Extra clamp required in this area
GID AS035a
(diagonally-crossed, green)
Extra support required in this area
GID AS036a
(transversal lines, blue)
Clamping point (middle of the clamp
GID AS037a
length)
Linear support
GID AS038a
ΔH
Clearance (height) between the bottom
edge of the module frame and the
mounting surface in millimetres (mm).
Dimensions
All dimensions are shown in mm. Note:
drawings are not always true to scale.
The numerical values are binding.
Page 12/19
Permissible
suction
2400 Pa
2400 Pa
frames
®
Permissible
suction
2400 Pa
2400 Pa
2400 Pa
aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany | [email protected]
Quick Reference Manual Rel. 4.2, 08/2015, en-GB-DE (1)