Video camera module A3101

Specifications:

Power supply: 26Vdc (supplied by A2101 /
A2102)
Power Consumption: 1W standby, 5W
active
Unlock Power output: 12Vdc, 250mA
Unlock time: 1~99s
Working temperature: 20ºC ~ +55ºC
Dimensions: 83(H) x 100(W) x 38(D)mm
A3101 Terminals
1. SET
DIP switches for system configuration.
2. JP-LK
Jumper for setting state of the NO contact
3. CN/KMB
Digital display module connection port
4. CN/T-COIL
Not in use
5. BUS
L1, L2 bus line connecting to terminal
BUS(DS) on the power supply
6. CN-LK
+12V
12VDC power output.
LK-
Power ground.
LK+
Common contact of the relay.
NO
Normally open/closed contact (use
JP-LK jumper to set)
EB+
Exit button connection port.
EB-
Exit button connection port.
7. CN/FUN
Not in use
8. CN/WGN
Not in use
3 |