Installation
Table 1: Maximum setpoint based on outdoor air temperature
Outdoor Air
Temperature (°F)
-30
-20
-10
0
10
20
30
40
45
>45
Outdoor Temperature Sensor Option 1 — Outdoors
To mount the Outdoor Temperature Sensor outdoors the signal wire will
need to penetrate an exterior wall. Use the following guidelines for proper
operation of the sensor:
Mount the sensor where:
there is good air circulation
wire distance between sensor and humidistat is less than 200 feet
it can measure true outdoor ambient air temperature
it is above the expected snow line
Do NOT mount the sensor:
in direct sunlight
where it may be covered by debris, snow, or ice
8
|
RESIDENTIAL HUMIDISTAT
Temperature (°C)
Outdoor Air
-34.4
-28.9
-23.3
-17.8
-12.2
-6.7
-1.1
4.4
7.2
>7.2
Adjusted Maximum
Humidity Setpoint
(RH%)
10
15
20
25
30
35
40
45
47.5
Unadjusted
Form 16763