Aleph QT-40 Руководство

Просмотреть онлайн или скачать pdf Руководство для Датчики безопасности Aleph QT-40. Aleph QT-40 2 страницы. Quad-tech intrusion detectors

Features
Feature
Table
Model
QT-40
QT-40SL
QT-60
Description
Available with 40-foot and 60-foot protection patterns, QT Series intrusion detectors provide high quality PIR+microwave security at an outstanding value.
Aleph's unique "QT" signal processing evaluates PIR and microwave information while factoring in ambient temperature and light for superior "Quad-Tech"
performance.
Installation
Select an installation height between 7 ft. (2.1 m) and 8.5 ft. (2.6 m). Optimum mounting height is 7.5 ft. (2.3m). Avoid aiming the intrusion detector
towards windows, areas exposed to direct sunlight, and heating/cooling outlets. For best performance, position the detector so its field of view is
unobstructed, and the anticipated path of an intruder will cross the PIR beam pattern.
Pet Immunity: For installations where pet immunity is needed, mounting height should be no lower than 7.5 ft. (2.3m). Animal access above floor level
(furniture, stairs...) may jeopardize the pet immunity feature of the detector.
To ensure Pet Immunity function, do not point detector towards stairways, furniture or room fixtures to which animals have access.
Separate the front and rear covers by first backing out the cover latch screw three to four full turns. Then use a small screwdriver or similar tool to release
the cover latch. To remove the PCB, push the PCB latch away from the board while grasping a terminal block and pulling the PCB out of the cover. Do
not pull on the microwave module. Refer to Figures 1 and 2, below.
Wire the detector to the control panel using 18 to 22 AWG conductor, standard non-shielded cable. Avoid running alarm wiring parallel to AC wiring.
Wiring knockouts and wire channel are provided in the rear cover for unobtrusive wiring. Terminal block configuration is shown in Fig. 3, below.
Adjustments
Prior to mounting the detector, configure jumper settings as required (see Fig. 2, below).
& Settings
Pulse Count: When Pulse Count jumper is covering both pins, PC is set at 2: two to three normal steps are required to trigger an alarm. Parking the
PC jumper on one pin (or removing jumper) sets PC to 4: four to five steps will trigger an alarm.
LED Enable: When Jumper is covering both pins, the Alarm LED is enabled. The Alarm LED glows through the lookdown lens when an alarm is
signaled at the Alarm Output terminals. LED brightness automatically increases when light level in detection area is high. As room light dims so does
the LED brightness. Parking the jumper on one pin (or removing jumper) disables the Alarm LED but has no effect on the alarm output.
Microwave Sensitivity: Microwave Sensitivity Adjustment is set to the fully clockwise position at the factory for maximum sensitivity (range).
Microwaves can "see" through walls, so in some cases, such as installation in a small room, it may be desirable to reduce microwave sensitivity.
Turn the Microwave Sensitivity Adjustment (Fig. 2) counter-clockwise to reduce sensitivity. Setting the adjustment to minimum (fully counter-clockwise)
reduces sensitivity to approximately one-third of its maximum value.
SL Front / SL Down: -- Included on Model QT-40SL -- These jumpers independently enable and disable the "Front" and "Down" Security Light (SL)
functions. SL Front controls a single white LED which shines through the front (wide angle) lens. SL Down controls two white LEDs which shine through
the lookdown lens. When enabled, Security Light operates for at least 10 seconds when motion is detected and room light is dim. Continued motion
will cause Security Light to remain on until approximately 10 seconds after motion ceases.
Fig. 1: Cover Component Layout
Front
Wide Angle Lens
Lookdown Lens
(Factory masked
for Pet Immunity)
Mounting Knockouts
Cover Latch Screw
Compliance Information:
QT Series
Quad-Tech Intrusion Detectors
Tamper
Lightning
Switch
Protection
X
X
X
X
X
X
Rear
Wiring Knockouts
Jumper Settings
Pulse Count
Jumper installed on both pins = PC 2
Jumper removed = PC 4
LED Enable
Jumper installed on both pins = LED ENABLED
Jumper removed = LED OFF
Security Light Enable*
Corner Mount
Jumper installed on both pins = SL ENABLED
Knockouts
Jumper removed = SL OFF
Wire Channel
Pulse
LED
60 lb. Pet
Count
On/Off
Immunity
Select
Select
X
X
X
X
X
X
X
X
Fig. 2: PCB Layout
PCB latch
Terminal Block
-
+
ALARM
TAMPER
Tamper
PULSE
COUNT
LED ENABLE
SL
FRONT
SL
DOWN
Alarm LED
*NOTE: SL features apply only to Model QT-40SL
Security
Temp.
Light
Comp.
X
X
X
X
Fig. 3: Wiring Configuration
Tamper
Terminal Block
Terminal Configuration
-
+
ALARM
Microwave
Module
Power
NC C
Microwave
Input
Sensitivity Adj.
30% ~ 100%
Input Voltage: 10 to 16VDC, 12VDC nominal
Max. input current: 15 mA; SL model 30 mA
Min.
Max.
Alarm Output: NC, 19VDC - 100 mA max
SL Front LED*
Tamper Output: NC, 30VDC - 500 mA max
SL Down LEDs*
All wiring must be in accordance
Tamper
with NEC, NFPA 70.
Switch
TAMPER
NC C