NSL-F Series Operating Manual
11

Technical data

Rod length EL
Measurement range
Process connection
Process pressure
Tightening torque
Materials
Temperature ranges
Resolution
Accuracy
Linearity
Reproducibility
Temperature drift
Response time t90
Electrical connection
Weight
Product-contacting
Thread
Tri-Clamp
Varivent
Connecting head
Threaded connector
Insulating part
Rod
Environment
Storage temperature
Process
CIP/SIP
Rod length >500 mm
Rod length <500 mm
Media with conductivity
>50 µS/cm (beer, milk)
Media with conductivity
<50 µS/cm
Rod length >500 mm
Rod length <500 mm
At 25°C
Supply voltage
Protection class
Output signal
Ohmic re-
sistance
Max. 3000 mm (NSL-F-00)
Max. 1500 mm (NSL-F-01 + NSL-F-02)
50...199 mm (rod diameter 6 mm)
200...max. EL (rod diameter 10 mm)
CLEANadapt G ½", G1" hygienic
1.5", 2", 2.5", 3"
DN 25 (type F) DN 40/50 (type N)
Max. 16 bar
10 Nm (CLEANadapt system)
Stainless steel 1.4308
Stainless steel 1.4305
PEEK (FDA approval: 21 CFR 177 2415)
Stainless steel 1.4404; Ra ≤0.8 µm
0...70 °C
-40...85 °C
-10...140 °C
143 °C max. 120 min
<0.1% of rod length
<0.5 mm
<1% of rod length
Depending on temperature, tank contour,
medium, distance to tank wall
<1.0% of rod length
<0.2% of rod length
<1.0 mm
≤0.1%
<100 ms
18...36 V DC
IP 69K
4...20 mA, galvanically isolated -> housing
0... 750 Ω
920 g at length of 1.5 m