Disconnect Type
Selects the power disconnect type to be used.
» "None" for disabling disconnect. Once powered on the port will be ON forever.
» "AC" for AC disconnects.
» "DC" for DC disconnects.
Violation Type
Selects the violation type to be used by the port during delivering state:
» "None" for bypassing violation checking.
» "Class Based" for limiting power based on the classification results. If classification is
» "User Defined" for limiting power based on user defined value.
Max Power
Enter the user defined power value. This value is used if the "Violation Type" is "User
Defined".
Power Inrush Control Selects the "Power Inrush" mode of the port:
» "Normal" for IEEE 802.3af mode.
» "High Inrush" for Legacy devices which require more than 15.4W.For port to deliver more
» "Pre 802.3at" for devices supporting 802.3at. For port to deliver more than 15.4W
Poll Status
Check to enable polling of port. Uncheck to disable polling.
Status
Port Status
Shows the port status. The status is color coded for easy identification.
» "Green" for delivering.
» "Blue" for searching.
» "Gray" for disabled.
» "Yellow" for Requesting Power
» "Orange" for Test mode.
» "Red" for Fault.
Class/Error Value
Shows the class being detected in case of normal operation. Also it shows the error value in
case of a fault condition.
Remote PD Type
Shows the Remote PD type.
Voltage
Shows the output voltage of the port.
Current
Shows the current being delivered.
Power
Shows the power being delivered
Temperature
Shows the junction temperature of the controller chip of that specific port.
Tech SupporT: 1.888.678.9427
bypassed then "Class-0" will be used in Normal Mode and "ILIM/ICUT" values in High
power mode.
than 15.4W appropriate ILIM/ICUT value needs to be selected and classification needs to
be bypassed.
appropriate ILIM/ICUT value to be selected.