INSTALLATION AND OPERATION MANUAL
IP CamERa-END
INsTaLLaTIoN (CLFE1UTP)
Off
Set the S1 10/100BaseT dip switch
to the appropriate rate based on the
On
required maximum data rate and
s1 s2 s3
maximum distance. oFF = 10BaseT;
oN = 100BaseT
Set the S2 Master/Slave dip switch to oN for "Master" mode
Set the S3 1- or 4-pair dip switch oN for 1-pair or oFF for
4-pair operation.
For systems not utilizing PoE, connect the 12V Power Supply
to the power connector of the CLFE1UTP. A power adapter
connector is provided to simplify connection.
CAUTION: If the external power adaptor is connected
with no power applied, the CLFE1UTP will not
recognize the PoE source and the system will be
inoperative.
Connect the IP camera RJ-45 connector to the 10/100BaseT
Ethernet port of the CLFE1UTP using a standard Cat5/6
cable, 100m length (max).
Connect one end of the long UTP cable to the RJ-45
connector of the CLFE1UTP.
The link LEd on the 10/100 connector should be "oN" to
indicate proper connection between the camera and the
CLFE1UTP.
TECh SUPPORT: 1.888.678.9427
EThERNET swITCh/NVR-END
INsTaLLaTIoN (CLFE1UTP)
Off
Set the S2 Master/Slave dip switch to
oFF for "Slave" mode
On
s1 s2 s3
Set the S1 and S3 dip switches to match
the setting on the camera-end.
CLFE4UTP, CLFE8UTP
1-P
and CLFE16UTP:
4-P
For each channel used, set the
s1 s2 s3 s4
appropriate dip switches for each
channel to match the camera end.
10
100
Note: Multichannel units are preset to
s1 s2 s3 s4
"Slave" mode. No adjustment required.
For systems not utilizing PoE, connect the 12V Power Supply
to the power connector of the selected CLFE(X)UTP.
Connect the RJ-45 connector of the Ethernet switch to the
10/100BaseT Ethernet port of the selected CLFE(X)UTP using
a standard Cat5/6 cable, 100m length (max).
Connect one end of the long UTP cable to the RJ-45
connector of the selected CLFE(X)UTP.
The Link LEd on the 10/100 Ethernet connector should be
"oN" to indicate proper connection between the switch and
the selected CLFE(X)UTP.
The Link LEd (Red for 100BaseT, Green for 10BaseT) will be
"oN" and not flashing to indicate confirmed connection
between the CLFE1UTP and selected CLFE(X)UTP extenders.
CLFE(X)UTP
INS_CLFEXUTP_REV–
09/28/11
PAGE 6