Error Messages
15.
Error Code
Err 3
Err 7
Err 8
Err 9
Err 10
Err 12
Ped
Abd
\\Cilaklfs1\shrdata\Masters\Installation Sheets\Laser\L160SD Installation Sheet.doc
Fault
No price or pump number set.
Excess flow.
Excess reverse rotation of encoder.
Faulty or disconnected meter encoder.
Configuration Lost
C4000 memory failure.
Display error
Page 13 of 16
Action
Set the pump number or:
Set a price at the pump or at
the controller.
Max Flowrate exceeded
Check product is not flowing
back into the tank once the
delivery has finished.
1.
Check that encoder is
plugged in.
2.
Replace encoder PCB on
meter
Reconfigure C4000 refer to
C4000 manual
Change memory IC.
F-AD-DS1225 (not applicable
to Futra)
1.
Check display cable for
loose wires/crimps
2.
Replace display PCB