Electrolux 30" Electric/Microwave Combination Wall Oven Руководство по установке - Страница 7

Просмотреть онлайн или скачать pdf Руководство по установке для Вентиляционная вытяжка Electrolux 30" Electric/Microwave Combination Wall Oven. Electrolux 30" Electric/Microwave Combination Wall Oven 21 страница. Gas cooktop
Также для Electrolux 30" Electric/Microwave Combination Wall Oven: Руководство по установке (16 страниц), Руководство по установке, использованию и уходу (22 страниц), Руководство по установке (28 страниц), Руководство по эксплуатации и уходу (36 страниц), Руководство по установке (25 страниц)

Electrolux 30
GAS COOKTOP INSTALLATION INSTRUCTIONS
(For 30" Models with 4 Sealed Burners, And Optional Electric Built-In Oven Combination)
Important:
Remove all packing material and
literature from cooktop before connecting gas and
electrical supply to cooktop.

Install Pressure Regulator

Install the pressure regulator with the arrow on the
regulator pointing up toward the unit in a position where
you can reach the access cap.
Do not make the connection too tight.
The regulator is die cast. Overtightening may crack the
regulator resulting in a gas leak and possible fire or
explosion.
All connections must be wrench-tightened
Figure 6
Assemble the flexible connector from the gas supply pipe
to the pressure regulator in the following order:
1. manual shutoff valve
2. 1/2" nipple
3. 1/2" flare union adapter
4. flexible connector
5. 1/2" flare union adapter
6. 1/2" nipple
7. pressure regulator
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
connectors are used, be certain connectors are not
kinked.
The supply line should be equipped with an approved
shutoff valve. This valve should be located in the same
room as the cooktop and should be in a location that
allows ease of opening and closing. Do not block access
to the shutoff valve. The valve is for turning on or
shutting off gas to the appliance.
Open the shutoff valve in the gas supply line. Wait a few
minutes for gas to move through the gas line.
Check for leaks. After connecting the cooktop to the
gas supply, check the system for leaks with a
manometer. If a manometer is not available, turn on the
gas supply and use a liquid leak detector (or soap and
water) at all joints and connections to check for leaks.
Do not use a flame to check for leaks
from gas connections. Checking for leaks with a flame
may result in a fire or explosion.
Tighten all connections if necessary to prevent gas
leakage in the cooktop or supply line.
Check alignment of valves after connecting the
cooktop to the gas supply to be sure the cooktop
manifold pipe has not been moved.
Disconnect this cooktop and its individual shutoff
valve from the gas supply piping system during any
pressure testing of that system at test pressures greater
than 1/2 psig (3.5 kPa or 14" water column).
Isolate the cooktop from the gas supply piping
system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig
(3.5 kPa or 14" water column).
7
Figure 7