Atlantic Alfea Extensa A.I. R32 Руководство по эксплуатации - Страница 13

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Тепловой насос Atlantic Alfea Extensa A.I. R32. Atlantic Alfea Extensa A.I. R32 20 страниц. Air/water split heat pump

Atlantic Alfea Extensa A.I. R32 Руководство по эксплуатации

Active functions

The "Active Functions" page tells you which services are operating and allows you to change their status.
- "Indoor comfort": Heating / Cooling / Stop.
- "Zone 1" / "Zone 2" / "Hot water" / " Emergency operation": ON / Stop.
If "Indoor Comfort" is set to "Stop", Zones 1 and 2 cannot be modifi ed.
"Emergency operation" : Activate only in case of error "370 : Thermodynamic
Generator". The appliance heats only with the electrical backup.

Temperature setting

The "Temperature setting" page allows you to set temperature setpoints for Comfort and ECO periods (heating and
cooling). Settings must be recorded for each zone.
Heating temperatures factory settings:
Comfort 20°C, ECO 19°C.
Cooling temperatures factory settings:
Comfort 24°C, ECO 26°C.
Some settings (or menus) might not be displayed. They are dependent on the installation's confi guration (and installed options).
alfea A.I. R32 / Operating manual / 2111 - EN

Active functions

Indoor comfort
Heating
Zone 1
ON
Zone 2
ON
Hot water
ON
Emergency operation
Stop

Temperature setting

Zone 1
Heating
21.5°C
Comfort T°
ECO T°
21.5°C
Cooling
Comfort T°
19.5°C
21.5°C
ECO T°
- 13 -