Electrolux E:Line ERCM9010AS Руководство по установке и эксплуатации - Страница 6
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Вентиляционная вытяжка Electrolux E:Line ERCM9010AS. Electrolux E:Line ERCM9010AS 12 страниц. Electrolux e:line canopy rangehoods
Также для Electrolux E:Line ERCM9010AS: Руководство по установке и эксплуатации (7 страниц)
electrolux e:line rangehoods rangehood installation / installation sequence 5
Rangehood installation
ERCM9010AS
ERCE9020AS
ERCG9030AS
Installation sequence
1. Using a spirit level mark a vertical centre line on the wall
where the hood is to be positioned, and a horizontal line
at the hood base position (refer diagram bottom left).
NOTE: The height of the underside of the hood body must be a
minimum of 600mm above an electric cooktop & 650mm above a
gas cook top and a maximum height of 800mm (see table right).
Distance from hood base to top of hob
hob type
minimum*
gas
650mm
electric
600mm
* If the instructions of the hob specify a greater distance than the
minimum above, then that shall be the minimum height for installation
2. M ark the location for the wall and ceiling bracket fixing
points above the hood base using the hood base as the
reference point (refer diagram left).
3. Install wall and ceiling mounting brackets with suitable
screws (to support a total weight of 30kg) to the wall at the
positions marked in diagram left.
4. Remove the protective plastic film from the hood body
and hang hood on the mounting brackets then secure at
the anti-tilt locations as indicated in diagram left.
Depending on the preferred installation/ducting mode,
follow step 5a or 5b below.
5a. R ecirculating mode (Fig. a). Using the centre line,
secure the ceiling mount bracket to the wall using
suitable screws. Attach the recirculating T-piece
(optional kit AR600RK for models ERCM9010 and
ERCE9020, or AR600RKG for model ERCG9030) to
the ceiling mount bracket. Install flexible pipe between
T-piece and fan transition outlet. Use cable ties or
suitable duct tape to secure flexible pipe to T-piece.
NOTE: When installed in recirculation mode, it is recommended
to use a carbon filter (included in recirculation kit AR600RK for
models ERCM9010AS and ERCE9020AS, or recirculation kit
AR600RKG for model ERCG9030AS, refer to page 9) to prevent
odours being emitted back into the room.
5b. D ucted mode (Fig. b). The canopy rangehood has been
supplied with flexible exhaust pipe and duct transition
piece, alternatively a 150mm dia. non-combustible flue
pipe can be used. Continue the centre line to the ceiling.
Attach the ceiling mount bracket on the centre line. Fit
preferred flue pipe to the fan transition duct.
(a)
ERCM9010AS & ERCE9020AS
ERCG9030AS
maximum
800mm
800mm
OR
(b)