If the cut-out continues to trip, replace the thermostat. Never by-pass the
safety device or the thermostat. Connect the power supply only via the
terminal.
The thermal cut-out fitted to the auxiliary electric heating element must be
replaced by an authorized agent. Failure to respect this clause invalidates
the warranty.
DANGER: The operation of the thermal cut-out indicates a possibly
dangerous situation. Do not reset the thermal cut-out until the water
heater has been serviced by a qualified person.
VS/HM Steatite
Adjusting the thermostat
Adjusting the temperature
The factory temperature setting
is 65° C.
The temperature may be lowered
by turning the wheel.
General maintenance
Parts that can be replaced
• Thermostat
• Cover
• Heater body (only for Steatite water heaters)
The seal must be replaced if the heater body is replaced or opened.
the manufacturer's original parts.
Potentiometer
-
+
-
+
• Heater element
• Seal
7
-
+