5.4)
Bio-energy system with Relax Digital as back-up
Install a 2-position 3-way valve in the existing heating flow
Install a room thermostat (TA-18.5degC) controlling gas/oil boiler & 3-way valve
If TA is less than 18.5degC, 3-way valve is in position B, gas/oil boiler is on
If TA is more than 18.5degC, 3-way valve is in position A, gas/oil boiler is off
Install second room thermostat at 19degC to control the Relax Digital
Set each boiler flow temperature at same value
5.5)
Weather-compensated Relax Digital systems