Dri-Air Industries ARID-X Руководство по эксплуатации - Страница 11

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Сушилка Dri-Air Industries ARID-X. Dri-Air Industries ARID-X 19 страниц. Floor mount dryers
Также для Dri-Air Industries ARID-X: Руководство по эксплуатации (20 страниц)

START-UP PROCEDURE

OPERATING MANUAL - ARID-X, HP4-X 150-300 FM DRYERS
Revision 10/8/02
DRI-AIR
INDUSTRIES, INC.

Standard Electrics

Turn Power on to Dryer:
1. Power light indicates power to the unit is on.
2. Illuminated Blower Light indicates Blower is on.
3. Flashing Zone light indicates bed is in
Regeneration cycle.
4. Steady Zone light means bed is in cooling cycle.
5. Illuminated Heater lights indicate heater is on.
Alarm Conditions:
6. Flashing High Temp. alarm indicates an over or
under temp alarm.
Unit shuts down.
7. Steady High Temp. Alarm light indicates unit has
failed. Further diagnostics are required

To Set Temperature:

Press SET button - temperature set display will flash.
Press up arrow to increase temperature and down arrow to
decrease temperature.
Press SET again to enter the new temperature.
If the display flashes, the temperature is out of the control
range.
If the display shows 0000 the thermocouple is not connected
or is faulty.
XX
Page 11