Fig. 3: Parts Identification
Condensate
drain outlet
Leveling foot-
pads (one on
each corner)
OPERATION
1.
Plug in the power cord into a standard 115V grounded
outlet. The unit must be operated on a 115V/60 Hz circuit
protected by a Ground Fault Interrupter (GFI) device.
2.
Attach one end of the drain hose to the condensate drain
outlet and directing the other end into a drain or away from
area to be kept dry. NOTICE: To prevent CMC100 drain
pan overflow, ensure that there are no kinks or sharp
bends in the drain hose and do not place the outlet of the
hose higher than 3 ft. (1 m) above the top of the CMC100.
3.
The CMC100 is controlled by an electronic touchpad hu-
midistat. The unit will automatically start when the humidity
of the surrounding air exceeds the humidity level selected.
4.
Set humidity set point with Control Panel (see below).
CONTROL PANEL
ON/STANDBY button
The ON/STANDBY button toggles the unit between the ON
and STANDBY modes. The display indicates the current mode.
1.
In the ON mode, the display shows the current measured
humidity as a percentage of relative humidity.
07-01637F F391-A 2012-01 Warranty 07-01651
Interchangeable pa-
nels. See Optional
Configurations, p. 2.
Processed air
outlet
Indicates normal
operating condi-
tions.
Display
ON/STANDBY
button
UP/DOWN
buttons
ON mode display
shows current hu-
midity
To view the current humidity setting, first set the unit in
the ON mode, and then press the UP or DOWN arrow
once.
UP button
To change the humidity setting, press the UP or DOWN
button twice. Each time you press the button, the value of
the humidity setting will increase or decrease in 5 percent
increments.
Note: In the ON mode, the display will show the humidity
setting only when you press the UP or DOWN buttons. Af-
ter you have finished adjusting the setting, the display will
resume indicating the measured humidity and the CMC
will automatically maintain humidity at the selected setting.
2.
In the STANDBY mode, the display shows a double dash.
Unit does not operate in this mode. Press the
ON/STANDBY button to return to ON mode.
Note: The UP and DOWN buttons do not function in the
Stand-by Mode. Press the ON/STANDBY button to
resume operation.
ADDITIONAL MODES
The CMC100 also has a DEFROST mode and a LOW TEM-
PERATURE PROTECTION mode. The unit automatically in-
itiates these modes as conditions warrant. No user intervention
is required.
1.
The CMC will automatically enter the DEFROST mode as
needed. The fan will continue to operate until the unit is
ready for the next operating cycle. The unit will automati-
cally return to ON mode when the defrost cycle is com-
plete.
2.
When the ambient temperature falls below 45°F (7°C), the
unit enters LOW TEMPERATURE PROTECTION mode
and stops operating. The unit will automatically restart
when the surrounding temperature rises above freezing.
Automatic water pump out
The unit automatically pumps out condensate through the con-
densate drain hose. No user intervention is required.
Note: Check for proper operation before leaving the unit unat-
tended. Do not move the CMC100 while it is operating.
3
DOWN button
STANDBY mode
DEFROST Mode
LOW TEMPERATURE PRO-
TECTION Mode
Dri-Eaz Products, Inc.