SERVICE
Cleaning the Filters
Each airstream passes through a filter just be-
fore entering the Energy Exchange core. The filter
catches and holds particulate matter, and is treated
to be resistant to fungus growth.
Clean the filters periodically. Remove either
side panel (four 5/16"-head bolts screwing into
permanently attached nuts) and pull the filters
away from the Velcro fastenings. Vacuum them,
blow them out with compressed air, or wash them
with water. Use a little detergent if needed.
Danger
Do not attempt to service or clean the Airchanger
while it is plugged into an electrical outlet. It is
dangerous for an unqualified individual to attempt
to disassemble or repair the unit.
Cleaning the Energy Exchange Core
Inspect the Energy Exchange Core regularly. If
it becomes dirty it can be cleaned.
IMPORTANT! Before removing the Core
from the Dri-X, remove the defrost control sensor
SPECIFICATIONS
Item
Power
Use Weight
Shipping Weight
Height x Weight x Depth
In-coming Airflow (no ducting)
Out-going Airflow (no ducting)
In-coming Airflow (12' of ducting)
Out-going Airflow (12' of ducting)
Defrost
Power Cord
Pump Hose
Specifications are subject to change without notice. Some values are approximate.
COPYRIGHT _ DRI-EAZ PRODUCTS, INC. 1997
wire probe from the core. After removing the filter
on the "Humid Air from Room" side, you will see
that the wire is inserted into one of the aluminum
corrugations. Pull it straight out of the Core and
leave it bent to one side. Replace it in the same
spot after cleaning the Core. When removing or
replacing the probe, be careful not to damage the
corrugations.
To remove the Energy Exchange Core, after
removing either side panel and removing the de-
frost control sensor probe, slide the Core straight
out. There is a handle on one end to assist in re-
moval. Clean with the soft brush attachment of a
vacuum cleaner. You can blow out the Core with
compressed air or the air output from a shop-vac,
being careful not to damage the corrugations.
Before removing the Energy Exchange Core from
the Dri-X, carefully remove the defrost control
probe according to directions. Failure to do so may
cause damage to the Core.
Specification
7.0 amps – 115 volts, 60 hz
132 lbs.
179 lbs.
27 x 24 x 46 inches
67 x 61 x 117 cm
325 cfm
304 cfm
280 cfm
244 cfm
Thermostatic
20 ft.
40 ft.
11
Warning
60 kg
74 kg
3
9.2 m
/min
3
8.6 m
/min
3
7.9 m
/min
3
6.9 m
/min
6.1 m
12.2 m