Atlantic Ultraviolet 10-0508B Руководство пользователя - Страница 5
Просмотреть онлайн или скачать pdf Руководство пользователя для Системы фильтрации воды Atlantic Ultraviolet 10-0508B. Atlantic Ultraviolet 10-0508B 20 страниц. Germicidal ultraviolet water purifiers
Также для Atlantic Ultraviolet 10-0508B: Руководство пользователя (16 страниц)
INSTALLATION
L
OCATION
1.
The water purifier is intended for indoor use only. The water purifier is designed to mount horizontally. The water purifier should
be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water
purifier, should be between 35
2. Electrical power supplied to the water purifier MUST match power requirements listed on the water purifier. Use of a voltage
surge protector is recommended.
3.
CAUTION: Install water purifier within 48" of a known good ground. Water Purifier will need to be installed into approved
ground fault circuit interrupt (GFCI) receptacle. Where a 2-prong or unprotected 3-prong receptacle is encountered, it must be
replaced by a properly grounded Ground Fault Circuit Interrupt (GFCI) receptacle. Installation must be in accordance with the
National Electrical Code and any local codes and ordinances by a qualified electrician.
4. The water purifier should be located in a dry, well-lit area, which provides enough room to perform routine maintenance.
This includes a minimum distance of one chamber length from the chamber end, to allow for cleaning and/or the
changing of the lamp and quartz sleeve as well as a minimum of 6" on the opposite end of the water purifier. Minimum clearance
to floor 18''.
5. The water purifier should always be located closest to the point of use. This reduces the chance of the purified water being re-
contaminated by bacteria in the water distribution system after the water purifier.
6.
CAUTION: As with any water handling device, the water purifier should be located in an area where any possible condensation
or leakage from the water purifier, any purifier accessory and/or plumbing will not result in damage to the area surrounding the
water purifier. For added protection, it is recommended that a suitable drain pan be installed under the purifier. The drain pan must
be plumbed to an adequate, free flowing drain to prevent water damage in event of a leak. There are numerous leak detection/
flood stop devices, available on the market today, designed to stop flow of water, reducing the chance of water damage due to
leakage. For more details regarding leak prevention and/or limiting damages due to leaks please contact factory.
7. The water purifier should be located after all other water devices, such as De-ionizers, Water Softeners, Carbon Filters, Pre-
Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This reduces the chance of the purified water being re-contaminated by
bacteria in any of these units.
8.
For 230v 50/60Hz water purifiers using ballast no.10-0504A, use Grounding Kit supplied (part no. 35-8300A).
See Figure 1- Grounding Kit below.
9.
We recommend checking with local codes or a licensed electrician in your area to determine the best grounding point to attach
the ground kit for your installation. Once a proper ground point has been determined, see "Grounding Kit Installation: 230v
50/60Hz (ballast no.10-0504A)" in the "Installation" section.
o
o
F and 100
F.
Figure 1 - Grounding Kit (35-8300A)
5