CAUTION
It is the user's responsibility to determine and validate the suitability of this equipment for use in the user's system or process. No
warranty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that
may be expected from its use. The user should periodically inspect, clean as necessary and confirm the presence and good legibility of
the product safety labels. Contact the factory for replacement labels in the event that any of the labels are missing or illegible.
PRODUCT APPLICATION
Construction
•
The water purifier is designed to mount horizontally.
•
The water purifier's dual chamber heads are removable and may be rotated independently, which aids in the installation,
maintence, or retrofiting of an existing system.
•
The water purifier's chamber and chamber head are passivated and electropolished type 316 Stainless Steel.
•
EASY-OFF
End Caps enable quick and easy lamp change, without disconnecting from the water supply or draining the
TM
purifier. No tools are required. Always disconnect electrical power when changing lamp.
Principle of Operation
The Bio-Logic
design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber.
®
The dosage, as it applies to ultraviolet disinfection, is a function of time and the intensity of ultraviolet radiation to which the
water is exposed. The exposure time, in seconds, is the total time it takes the water to flow through the disinfection chamber
exposing it to the germicidal lamp. Exposure time is related to the flow rate; the higher the flow rate, the lower the exposure time
or the lower the flow rate, the higher the exposure time. The ultraviolet intensity is the amount of energy, per unit time, emitted by
the germicidal lamp. The dosage is the product of ultraviolet intensity and the exposure time. The operation of the Bio-Logic
as follows:
•
Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall.
•
Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp.
•
The LED indicator light, located on the ballast, provides visual indication of germicidal lamp operation.
•
Water leaving the purifier is instantly ready for use, no further contact time is required.
Limitation of Use
The water purifier is intended for the use with visually clear water, not colored, cloudy or turbid. See "Water Quality" section
below. The water purifier is NOT intended for the treatment of water that has an obvious contamination or intentional source,
such as raw sewage; nor is the unit intended to convert wastewater to microbiologically safe drinking water.
Water Quality
Water quality plays a major role in the transmission of germicidal ultraviolet rays. It is recommended that the water does not
exceed the following maximum concentration levels:
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added
measures to improve water quality to treatable levels. If, for any reason, it is believed the ultraviolet transmission is not
satisfactory, contact the factory.
4
Table 1 - Maximum Concentration Levels
Turbidity
Manganese
Total Suspended Solids
pH:
Color:
Hardness
Iron
Tannins:
UV Transmission
* Contact Factory for recommendations on applications where UV transmission is < 85%
< 1 NTU
0.05 mg/1
10 mg /1
6.5 - 9.5
None
6 GPG or 102.6 PPM
0.3 mg/1
< 0.1 ppm (0.1 mg/l)
>85% per cm*
is
®