MAINTENANCE

Always disconnect power to the fixture before performing any service or maintenance.
The SANITAIRE
is designed to operate with a minimal amount of maintenance.
®
A regular cleaning cycle of the STER-L-RAY
established, and carefully maintained, based on inspection and experience. The frequency of cleaning will vary with the
conditions surrounding each installation. It is recommended that the ultraviolet lamp(s) be cleaned at least once every
three (3) months.
The STER-L-RAY
Germicidal Ultraviolet Lamp(s) used in the SANITAIRE
®
life of 10,000 hours. Lamps may operate longer than their rated effective life, but the reduction in ultraviolet output will make
it impractical to use past the manufacturer's rated life. For maximum efficiency lamp replacement is recommended every
10,000 hours of operation or about one (1) year of continuous use.
Unless lamp replacement is due to failure or breakage, it is recommended that all lamps be replaced at the same time.
Do not override the safety interlock switch. Operation of the fixture with the interlock switch
overridden and the Access Door open will expose personnel to direct or strongly reflected germicidal ultraviolet rays.
Germicidal ultraviolet rays are harmful to the eyes and skin.
r
s
equired
uPPlies
Vacuum cleaner
Detergent
Water
Soft, clean, lint-free cloth
Denatured alcohol
u
l
i

nit and

amP
nstallation
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY
EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
Always disconnect power to the fixture before performing any service or maintenance.
Ultraviolet lamp(s) are easily damaged and may cause injury if broken. Exercise care when handling.
1. Disconnect power to the fixture and unplug from the electrical outlet.
2. Remove STER-L-RAY
stationary lampholder pull lamp out, and away from unit.
3. Moisten a clean, lint-free cloth with denatured alcohol and clean STER-L-RAY
4. When STER-L-RAY
®
interior of the unit with a soft dry cloth, or vacuum.
5. To remove any dust, dirt, fingerprints, smears, etc, from the outer surfaces of the SANITAIRE
moisten a clean, lint-free cloth with denatured alcohol and wipe down the unit. Buff out any streaks, left from the cleaning,
using a soft dry cloth.
6.
Install STER-L-RAY
the spring-loaded lampholder. Align upper lamp pin with stationary lampholder. Slowly ease the pressure until lamp is
fully seated in lampholders.
7. Verify that STER-L-RAY
8.
Repeat until all STER-L-RAY
9.
Restore power to the fixture.
Germicidal ultraviolet rays are harmful to the eyes and skin.
10. Verify operation by viewing lamp(s), use of personal protection equipment is required. If the unit is not operating properly,
go to "Troubleshooting" section.
Germicidal Lamp(s), interior, sight glass and intake filter(s) MUST be
®
, r
ePlaCement
lamp(s), carefully press lamp against the spring-loaded lampholder, when upper lamp pin clears the
®
lamp(s) have been removed, cleaned and safely set aside, remove any loose dust or dirt from the
lamp(s), insert lamp pin into spring-loaded lampholder. Carefully press lamp against
®
lamps are properly seated.
®
lamps have been properly reinstalled.
®
Avoid exposure to direct or reflected germicidal ultraviolet rays.
have a manufacturer's rated average effective
®
,
C
or
leaning
lamp(s).
®
Room Air Sanitizer,
®
9