installing the hood
Mounting
the duct cover bracket
The duct bracket should be installedagainst the
back wall and flush with the ceiling. This bracket will
hold the telescopic duct cover in place at the top
(this a extra accessory available not included with the
hood).
Secure the bracket to the wall:
Align the marked centerline on the bracket with
the centerline on the wall.
Mark 2 screw hole locations in the wall.
Drill 5/16" pilot holes in the marked locations.
Install wall fastener anchors.
Drive wood screws, by hand, into the fastener to
allow anchors to expand. Remove the screws.
Secure the bracket to the wall with wood screws
and/or fasteners.
J
/
i
d)
/
Ceiling ducting
If the duct will vent straight up to the ceiling:
Use level to draw a line straight up, from the
centerline on the template to the ceiling.
Measure at least 4 -12/16 "from the back wall to
the circle center of an 8-1/2"hole on the ceiling.
Wall ducting
If ductwork
will vent to rear:
Use a level to draw a line straight up from the
centerline on the template.
Measure at least 23 - 12/16" (the measure might
vary depending on the elbow used) above the
pencil line that indicates the bottom installation
height, to the circle center of an 8-1/2, diameter
duct hole (Hole may be elongated for duct elbow).
House wiring location
= The junction box is located on the top left side of
the hood.
Wiring should enter the back wall at least 20"
above the bottom of the installation height, and
within 5-7/8" and 4-7/8"of the left side of the
centerline.
-=.t_Lf------'_
- FORCEILING VENTDUCTING
4-3/4"circle
center to wall
_
/
i
WALL ._(
_
Circlecenterat23 3/4"
VENT
\
J"
_0ve
the marked bottom
DUCT
_J
pencil line.
o
o
Horizontal s traight
pencilline