Electrolux RS-600 A-S Руководство по установке и эксплуатации - Страница 3
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Вентиляционная вытяжка Electrolux RS-600 A-S. Electrolux RS-600 A-S 5 страниц.
•
When assessing the measures necessary, always take the
entire ventilation system of the house into consideration. In
case of doubt, ask your local chimney sweeper for help.
•
Never secure the cooker hood to a ventilation duct, or a room
or exhaust gas chimney! Do not let the air that is removed from
the room be drawn into a duct where warm air is circulating.
The extracted air should only be drawn outdoors through a
separate ventilating duct that is only for the extractor hood.
•
When in extraction mode, air in the room is being removed
by the cooker hood. Please make sure that proper ventilation
measures are being observed. The cooker hood removes
odours from room but not steam.
•
There shall be adequate ventilation of the room when the
range hood is used at the same time as appliances burning
gas or other fuels (not applicable to appliances that only
discharge the air back into the room).
•
The air must not be discharged into a flue that is used for
removing fumes from appliances burning gas or other fuels
(not applicable to appliances that only discharge the air back
into the room).
Cleaning
•
There is a fire risk if cleaning is not carried out in accordance
with the instructions.
•
Pay attention to the sharp edges inside the cooker hood,
especially during cleaning.
•
Always disconnect the power supply prior to cleaning the
cooker hood. If the switched fused connection unit is difficult
to reach, shut off the power supply by using the corresponding
circuit breaker at the distribution board.
•
Keep the cooker hood clean. Fat deposits could catch on fire
when exposed to high temperatures.
3. INTENDED USE
•
Your cooker hood can be operated in recirculated-air
operation or in exhaust operation.
Recirculated-air: Kitchen fumes are removed and after
•
purification are fed back into the room through the upper air
outlet openings. The purification takes place via the grease
filters.
4. PARTS SUPPLIED
No.
Part
1
Cooker hood
2
Upper and lower chimney
3
Upper bracket
4
Lower bracket
5
Collar
RS-600 (CHS60SS)-GB-05.indd 3
No.
Part
6
Light bulb (E14)
7
Long screw (4mm x 32mm)
8
Wall plug
9
Short screw (3.8mm x 12mm)
5. INSTALLATION
•
Important! We recommend that two people carry out the
installation. Pay attention to the procedure described in the
assembly instructions.
Preparation
•
Exhaust operation: The wall breakthrough (core drill hole,
min. 125mm) must be carried out by a professional prior to
installing the extractor hood.
Pay attention to the length of the exhaust hose when
planning the wall breakthrough. The exhaust hose must
reach the outer edge of the wall without any kinks.
Important! If the exhaust hose leads through an outer wall,
the air outlet on the outside must be equipped with a cover
that has self-opening slits (not supplied). This can be installed
by the company that performs the wall breakthrough.
If open fireplaces are operated in the same room, ask your
local chimney sweeper about the local regulations prior to
installation.
If you are renting, then approval must be obtained from the
owner of the property.
•
Attention! In order for the cooker hood to reach optimal
performance, mount it over the middle of the cooking area.
•
Plan the power connection prior to installation so that a
disturbing cable will not be visible afterwards.
•
The following accessories are required to mount the cooker
hood (not included with the delivery):
Exhaust duct
Power drill
Screwdriver
Water level
Cable detector
Qty.
Electrical connection
1
•
All fittings must be installed by a qualified electrician in
accordance with current IEE Wiring Regulations (BS7671) and
local building regulations.
•
Important! Always switch off the electricity supply at the
mains during installation and maintenance. We recommend
that the fuse is withdrawn or circuit breaker switched off at
1
the distribution board whilst work is in progress.
+
•
Prior to drilling holes to secure it to the wall, make sure that
1
no cables or pipes will become damaged (electric, gas, water,
etc.; test the areas in question with a cable detector).
•
This unit is double insulated and must not be earthed. If there
1
are any incoming earth cables, they must be joined and well
insulated with good quality insulation tape. This is to ensure
earth continuity throughout your property.
•
Means for disconnection must be incorporated in the fixed
1
wiring in accordance with the wiring rules. To achieve this
install appropriate switched fused connection unit.
1
3
Qty.
2
8
8
4
6/8/2010 9:31:01 AM