Electrolux SL series Используйте - Страница 39
Просмотреть онлайн или скачать pdf Используйте для Вентиляционная вытяжка Electrolux SL series. Electrolux SL series 45 страниц.
Setting of the suction use: if the hood is set for filtering use, with motor and lights off keep
pressing for 5 seconds the push buttons
/
; the led point of the
push button will switch
on for 5 seconds.
MAINTENANCE
CLEANING OF GREASE FILTERS
The metallic grease filters are used to trap the grease that in normal use is contained in the
kitchen vapours/fumes, thereby avoiding the deterioration of the motor.They can be
handwashed or washed in the dishwasher.
For washing by hand, use hot water and soap; this can be done by hand brushing vigorously
several times and then rinsing under the tap.
After washing, the grease filters should be dried and re-fitted correctly.
It is possible that after washing the filter colour changes slightly.
WARNING! We recommend washing grease filters after 50-100 hours of use of
the hob.
If grease filters are dirty, motor can take in just a small quantity of air and performance is
reduced.
The grease which accumulates on dirty filters is easily inflammable and can cause fires, if
not eliminated by periodic washes.
The manufacturer declines any responsibility for fires caused by poor maintenance of
the grease filters.
CARBON FILTERS
The carbon filters are used when the hood is in filtering version. The carbon sets the air free
from kitchen odours. The carbon filters are to be found behind the grease filters and are
necessary if the hood is used in filtering version.
It is not necessary to use carbon filters, if the hood is used for suction use.
We have kinds of carbon filters: LONG LIFE Carbon filters that can be regenerated and
Standard Carbon Filters that cannot be regenerated.
LONG LIFE CARBON FILTERS
For carbon filter that can be regenerated you find an instruction with the filter.
The carbon filter that can be regenerated is marked with 230 °C on the frame.
INSTRUCTIONS: the carbon must be regenerated before the first use as the carbon, even if
special active carbon, takes on humidity. The humidity must be taken away.
Put the filter cassette on the grill of your oven and let is warm up for 1 hour at 230°C. Then
wait for 2 hours to let it become completely cold. If the filter is remounted before 2 hours the
hood can be damaged by remains of hot carbon. The process of regeneration can cause a
light change in the colour of the filter cassette. After this time the filter can be remounted in the
hood.
REGENERATION
Humidity and grease particules reduce the performances of air delivery and for this reason the
filter must be regenerated according to the time given in the instruction booklet.
Put the filter- cassette on the grill of your oven and let it warm up for 1 hour at 230°C. Then
wait for 2 hours to let it become completely cold. Only after this time the filter can be
remounted and your hood can work for other 4 months. If you use the hood in an intensive
39