Atlas Copco ETD MT41-100-I06 Инструкции к продуктам - Страница 5

Просмотреть онлайн или скачать pdf Инструкции к продуктам для Электроинструмент Atlas Copco ETD MT41-100-I06. Atlas Copco ETD MT41-100-I06 16 страниц. Handheld transducerized

Atlas Copco ETD MT41-100-I06 Инструкции к продуктам
ETD MT41-100-I06

Bit grounding test

Bit grounding is measured by the ground circuit stability and resistance with the tool running at no load
with a rotation speed of 200 rpm. Resistance is measured between the special bit 4216 2194 00 and the
outside of the tool connector and the resistance limit is 20 Ω.

Service Overview

Service Recommendations

Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guide-
lines:
Clean appropriate parts accurately
Replace any defective or worn parts

Preventive maintenance

Recommended interval between actions:
Valid at normal usage of the tool at a load up to 70% of maximum torque.
Service should only be carried out by trained technician following provided service instructions and
using original Atlas Copco spare parts.
EN
© Atlas Copco Industrial Technique AB - 9839 1064 01
Product Information
5