Bose RoomMatch Руководство по установке - Страница 13
Просмотреть онлайн или скачать pdf Руководство по установке для Акустическая система Bose RoomMatch. Bose RoomMatch 24 страницы.
pro.Bose.com
5-Module (60° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
14
RMxx05
5
20
RMxx10
0
25
RMxx20
-5
30
RMxx20
-10
32
-15
n/a
-20
n/a
-25
n/a
5-Module (80° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
15
RMxx05
5
20
RMxx10
0
25
RMxx20
-5
30
RMxx40
-10
32
-15
n/a
-20
n/a
-25
n/a
6-Module (60° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
17
RMxx05
5
23
RMxx10
0
29
RMxx10
-5
32
RMxx10
-10
n/a
RMxx20
-15
n/a
-20
n/a
-25
n/a
6-Module (80° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
19
RMxx05
5
25
RMxx10
0
31
RMxx20
-5
32
RMxx20
-10
n/a
RMxx20
-15
n/a
-20
n/a
-25
n/a
Large Array Frame: 5 Modules
Predicted
Array
Pitch
Modules
11.0
RMxx10
5.1
RMxx10
RMxx10
0.2
-4.8
RMxx20
-6.7
RMxx20
n/a
n/a
n/a
Predicted
Array
Pitch
Modules
RMxx05
10.1
5.2
RMxx10
0.3
RMxx10
RMxx20
-4.7
-6.6
RMxx40
n/a
n/a
n/a
Large Array Frame: 6 Modules
Predicted
Array
Pitch
Modules
RMxx05
10.1
5.3
RMxx05
0.3
RMxx10
RMxx10
-2.2
n/a
RMxx20
n/a
RMxx20
n/a
n/a
Predicted
Array
Pitch
Modules
10.3
RMxx05
RMxx05
5.3
0.2
RMxx05
-0.7
RMxx10
RMxx20
n/a
n/a
RMxx40
n/a
n/a
Simplified Load and Pitch Limit Charts
5-Module (70° Total V)
Desired
Pickup
Predicted
Pitch
Point
Pitch
10
20
10.3
5
25
5.3
0
30
0.2
-5
32
-1.9
-10
n/a
n/a
-15
n/a
n/a
-20
n/a
n/a
-25
n/a
n/a
5-Module (85° Total V)
Desired
Pickup
Predicted
Pitch
Point
Pitch
10
17
10.1
5
22
5.1
0
27
0.1
-5
32
-4.9
-10
n/a
n/a
-15
n/a
n/a
-20
n/a
n/a
-25
n/a
n/a
6-Module (70° Total V)
Desired
Pickup
Predicted
Pitch
Point
Pitch
10
17
10.6
5
23
5.7
0
29
0.7
-5
32
-1.8
-10
n/a
n/a
-15
n/a
n/a
-20
n/a
n/a
-25
n/a
n/a
6-Module (85° Total V)
Desired
Pickup
Predicted
Pitch
Point
Pitch
10
16
10.0
5
22
5.2
0
28
0.3
-5
32
-3.0
-10
n/a
n/a
-15
n/a
n/a
-20
n/a
n/a
-25
n/a
n/a
5-Module (75° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
18
RMxx10
5
23
RMxx20
0
28
RMxx20
-5
32
RMxx20
-10
n/a
-15
n/a
-20
n/a
-25
n/a
5-Module (90° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx10
10
20
RMxx10
5
25
RMxx10
0
30
RMxx20
-5
32
RMxx40
-10
n/a
-15
n/a
-20
n/a
-25
n/a
6-Module (75° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
20
RMxx10
5
26
RMxx10
0
32
RMxx10
-5
n/a
RMxx20
-10
n/a
RMxx20
-15
n/a
-20
n/a
-25
n/a
6-Module (90° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
17
RMxx05
5
23
RMxx10
0
29
RMxx10
-5
32
RMxx20
-10
n/a
RMxx40
-15
n/a
-20
n/a
-25
n/a
Installation and Safety Guidelines
Predicted
Pitch
10.9
5.9
0.8
-3.3
n/a
n/a
n/a
n/a
Predicted
Pitch
10.4
5.4
0.3
-1.8
n/a
n/a
n/a
n/a
Predicted
Pitch
10.4
5.5
0.4
n/a
n/a
n/a
n/a
n/a
Predicted
Pitch
10.6
5.7
0.7
-1.8
n/a
n/a
n/a
n/a
Page 13