DROPSA Dragon Series Руководство по эксплуатации и техническому обслуживанию - Страница 3

Просмотреть онлайн или скачать pdf Руководство по эксплуатации и техническому обслуживанию для Водяной насос DROPSA Dragon Series. DROPSA Dragon Series 13 страниц.
Также для DROPSA Dragon Series: Руководство по эксплуатации и техническому обслуживанию (12 страниц)

DROPSA Dragon Series Руководство по эксплуатации и техническому обслуживанию

4. TECHNICAL CHARACTERISTICS

Empty weight
Motor power supply
Rated motor power
Degree of motor protection
Minimum level
Optical power supply level
Optical level output signal
Optical LED signal
Level connector (optical- floating switch)
Float Level output signal
Pressure switch
Pressure switch output signal
Pumping system
Flow rates (1500 rpm)
Maximum operating pressures
Outlet connection
Tank capacity
Filter
By-pass
Temperature of use
Operating humidity
Permitted lubricants *
Storage temperature
Continuous sound pressure level
N.b. The specifications refer to the temperature of use of +20°C (+68°F)
(1)
revolutions with load less motor
* If a different product is used, please contact Dropsa S.p.A. to ensure it is suitable for use (see page 12)
GENERAL CHARACTERISTICS
6.2 Kg
ELECTRICAL CHARACTERISTICS
230-400 V - 50 Hz
265-460 V - 60 Hz
110 V 50 Hz single phase 4p
230 V 50 Hz single phase 4p
24 V CC 2800 rpm
0.09 Kw – 0.11 Kw
IP 55
Optical (oil and fluid grease versions ) / With floating switch (only oil
version)
8÷28 V DC inversion protected
Type NPN/PNP short-circuit protected, off in the case of minimum
level. Max 1.7A
Active when tank is not empty
DIN 43650
Clean contact 50V max voltage, 40 W max power. SPDT
Contact closed in the case of max calibration pressure alarm
(3-18-30 bar)
Voltage free contact max voltage 42V, max. power 100 W
HYDRAULIC CHARACTERISTICS
Gear pump
350 cc/min - 500 cc/min (three-phase/single-phase versions)
600 cc/min - 850 cc/min (24V
- 70 bar -three-phase motor (with intermittent service max 5 min
with pause ratio 1:1)
- 40 bar (single-phase motor)
- max 30 bar with continuous service
G1/8" BSP
3L/6L
Degree of filtering 1000 µ
Adjustable 0 ÷70 bar – precalibrated 40bar (35bar for single-phase
motors)
+ 5  + 70 C
90 % rel. humidity
Mineral lubricating oil 32 cSt; grease max NLGI000
-20  +65 °C
< 70 dB(A)
three-phase
(1)
DC
)
version
Contact.
3