DROPSA VIP4Air 24 V DC Руководство по эксплуатации и техническому обслуживанию - Страница 8
Просмотреть онлайн или скачать pdf Руководство по эксплуатации и техническому обслуживанию для Системы смазки DROPSA VIP4Air 24 V DC. DROPSA VIP4Air 24 V DC 16 страниц. Minimal air/oil lubrication system
9.3 MOUNTING THE MINI-PUMPS ON THE MIXER BASES (for replacement or augmenting)
The mini-pumps are mounted on the mixer bases utilizing two securing screws.
Particular attention should be paid to the correct positioning of the o-rings between the mini-
pump and the mixer base (see diagram below).
9.4 MOUNTING OF THE MIXER ASSEMBLY ON THE VIP4TOOLS (for replacement or augmenting)
To install a new unit proceed as follows:
1. Empty the tank of oil.
2. Disconnect the air supply and unscrew the connections on the base.
3. Connect the new base tightening the two securing screws supplied, paying particular
attention to the alignment and positioning of the seals.
4. Reattach the connections to the new base.
9.5 HYDRAULIC CONNECTIONS
The only connection to be undertaken is that of the individual pumps, provided with push-in
connections, to the lubrication point. The tubing must be in Ø4 mm nylon (obtainable from
Dropsa).