1. INTRODUCTION
This manual refers to FLOW MASTER volumetric flow device.
You can find additional copies and newer revisions of this document from our website http://www.dropsa.com. Alternatively
contact one of our Sales Offices.
This User and Maintenance Manual contains important information on health and safety issues for the personnel.
It is recommended to attentively read this manual and carefully keep it in good condition so that it is always available to
personnel requiring to consult it.
2. GENERAL DESCRIPTION
FLOW MASTER is a volumetric flow meter, which constantly monitors lubrication.
Flow meter precise monitoring, without calibrations or adjustments, is due to volumetric measurements not dependent on
lubricant temperature or viscosity.
FLOWMASTER is a modular system consisting of two elements:
Base
Metering module
MODULAR SYSTEM
The base is common to all size modules, which are also interchangeable. The modular construction makes it possible to built
assys (base and metering module) of 20 modules or more.
OPERATING PRINCIPLE
A "satellite", which rotates with a fixed orbital movement, is operated by the liquid passage through the metering module. An
inductive sensor picks up each orbital movement and transmits a signal to an electronic reader. The operator can read the
output of the metering module in litres/min or in rev/min directly from the FACT 2000 device-display or from a PC monitor.
VISUAL INDICATION OF THE FLOW OF LIQUID
A "satellite", built in the module body, rotating with an orbital movement indicates the fluid velocity. The flow output is neither
reduced nor interrupted even if the "satellite" stops.
3. PRODUCT - MACHINE IDENTIFICATION
Machine identification red label is located on the front side of the unit and contains machine serial number.