H5KLR-8
(
INPUT
)
(
RESET
)
4
5
3
6
OUT2
2
7
1
8
(
)
0V
SOURCE
NPN type
H5KLR-8I
(
)
INPUT
(
)
RESET
4
5
3
6
OUT2
2
7
1
8
(
+VDC*
)
SOURCE
PNP type
One-shot output from Output 1
Output :
Self-holding output
N
Up
Output mode
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Output and present value display are maintained until reset.
F
Up
Output mode
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Present value display runs continuously. Outputs are maintained until reset.
C
Up
Output mode
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Present value is placed in reset start status as soon as count up is reached. The count up is not displayed.
Outputs are 1-shot and operate repeatedly. Output 1 is self-holding, and goes off after expiration of the 1-shot
period for Output 2. One -shot time periods for Output 1 and 2 are independent.
R
Up
Output mode
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Present value is placed in reset start status as soon as count up is reached. Outputs are 1-shot and operate
repeatedly. Output 1 is self-holding, and goes off after expiration of the 1-shot period for Output 2. One -shot
time periods for Output 1 and 2 are independent.
H5KLR
H5KLR
RUN
OUT1
OUT2
RESET
Set1
CP1
Set2
CP2
K/P
RESET
H5KLR-8B
(
INPUT 2
)
(
)
INPUT 1
(
RESET
)
4
5
3
6
OUT2
2
7
1
8
(
)
0V
SOURCE
NPN type
H5KLR-8BI
(
)
INPUT 2
(
INPUT 1
)
(
)
RESET
4
5
3
6
OUT2
2
7
1
8
(
+VDC*
)
SOURCE
PNP type
One-shot output from Output 2
Self-holding output
Down
Up / Down A.B.C
Down
Up / Down A.B.C
Down
Up / Down A.B.C
Down
Up / Down A.B.C
ANLY ELECTRONICS CO., LTD.
CONNECTION
H5KLR-8M
(-)
(+)
+ VDC*
Load
(Sensor)
(50 mA)
CP1
4
5
3
6
(
INPUT 1
)
OUT2
CP2 /
2
7
RESET
1
8
(
INPUT 2 /
)
RESET
(
0V
)
SOURCE
NPN type
*For H5KLR-11M, H5KLR-8I,
H5KLR-8BI, H5KLR-11I and
H5KLR-11MI, the supply
voltage (+VDC) is 9V, when
the operating voltage
(SOURCE) is 12~48V.
The supply voltage (+VDC)
is 12V, when the operating
voltage (SOURCE) is 100~
240V.
TIMING CHART
K
Up
Output mode
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Present value runs continuously. Output 1 is self-holding, and goes off after expiration of the 1-shot period for
Output 2. One-shot time periods for Output 1 and 2 are independent.
P
Up
Output mode
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Present value display does not change during 1-shot time period, but reset start status is returned to as soon
as count is reached. Outputs are 1-shot and operate repeatedly. Output 1 is self-holding, and goes off after
expiration of the 1-shot period for Output 2. One -shot time periods for Output 1 and 2 are independent.
Q
Up
Output mode
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Present value runs continuously through 1-shot time period and returns to reset start status immediately
afterward. Outputs are 1-shot and operate repeatedly. Output 1 is self-holding, and goes off after expiration
of the 1-shot period for Output 2. One -shot time periods for Output 1 and 2 are independent.
A
Up
Output mode
Reset
9999
Preset 2
Preset 1
0
Output 1
Output 2
Present value and output 1 maintain status until reset. Output 1 and 2 operate independently.
DIMENSION(mm)
H5KLR + Y-50 + US-08
RUN
OUT1
OUT2
RESET
CP1
CP2
RESET
+0.5
45
-0
http://www.anly.com.tw
H5KLR-11
CP1
RESET
6
5
7
4
8
3
9
OUT1
OUT2
2
10
1
11
SOURCE
NPN type
H5KLR-11I
CP1
RESET
6
5
7
4
8
3
9
OUT1
OUT2
2
10
1
11
SOURCE
PNP type
Down
Down
Down
Down
H5KLR
Set1
Set2
K/P
H5KLR-11M
(RESET)
RESET
(INPUT 2)
CP2
(INPUT 1)
CP1
6
5
7
(K/P)
4
8
K / P
3
9
Common (0V)
(0V)
OUT2
2
10
1
11
(-)
(+)
Load
(Sensor)
+VDC*(50 mA)
SOURCE
NPN type
K / P : Key Protection
H5KLR-11MI
(RESET)
RESET
(INPUT 2)
CP2
(INPUT 1)
CP1
6
5
7
(K/P)
K / P
4
8
(+)
(-)
3
9
Load
OUT2
(Sensor)
2
10
1
11
+VDC*(50 mA)
SOURCE
PNP type
K / P : Key Protection
Up / Down A.B.C
Up / Down A.B.C
Up / Down A.B.C
Up / Down A.B.C
45
+0.5
-0
M-H5KLR_I-G-A