Daishiba DSP? 85HA Руководство по установке и эксплуатации - Страница 13
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Насос для плавательного бассейна Daishiba DSP? 85HA. Daishiba DSP? 85HA 17 страниц. Air source swimming pool heat pump
◆
Up / Down
Up / Down buttons are used to raise or reduce set water temperature, adjust the time of the
clock and the timer, reset part of parameter in the management level
The outlet water temp adjustment range from 25 ℃~60℃;
◆
Off timer / On timer
Press these two buttons to adjust timer.
When at the heating mode or shut down, press the timer on button for more than tem 10
seconds, the system will enter into defrosting mode forcibly and the words "defrosting" will be
shown on the screen; press "ON / OFF" to quit defrosting mode compulsively.
Note: the unit is of defrosting automatic function, so only when defrosting incompletely in
winter is the compulsively defrosting needed. This operation must be forbidden usually.
◆
Mode
Press this button to change heating/cooling mode.
◆
Inquiry
Press this button to inquire temperature of each detector; or adjust and reset some parameters
of the unit license
Press the "Inquiry" button, entering into the parameter checking mode
Water outlet temp
Water back temp
Outer ambient temp
Outer coil 1 temp
Compressor back 1 temp
Input state
Compressor stop unrecoverable fault code
Compressor stop restorable fault code
Item
- 12 -
Code
d01
d02
d03
d04
d06
d08
d09
d10