Important Safety
1.
Before installation, maintenance or lamp replacement, ensure that the mains supply to the luminaire is switched off and
the circuit supply fuses are removed or the circuit breaker is turned off.
2.
It is recommended that only a qualified electrical contractor carries out the installation of this luminaire and that the
luminaire is installed in compliance with the current edition of the IEE Wiring Regulations.
3.
The person carrying out the installation is to check and verify that the total load on the circuit, including that of this
luminaire does not exceed the rating of the circuit cable, fuse or circuit breaker.
4.
Where a luminaire incorporates discharge control gear (inductive load), the circuit capacity and ratings require careful
sizing to avoid nuisance tripping of the protective device used in the installation.
5.
Where applicable, careful consideration should be taken during installation to ensure that all fixings and/or suspensions
are of a suitable size for the luminaire being installed.
Ratings
1. All luminaires are manufactured & tested in compliance with the requirement contained within BS EN 60598 and are CE marked.
2. All luminaires that are of Class 1 construction and that are marked accordingly, MUST be earthed.
3. All luminaires are designed to operate at 230Volts AC -6%/+10% = 216Volts to 252Volts. Do not operate outside these voltages.
4. All luminaires are only suitable for applications within their rated Ingress Protection limits as stated.
o
5. Max ambient temperature 25
Exclusions to Warranty
Please Note - The limited warranty shall be null and void in the following circumstances:-
Failure by the installer, end user or any third party to exercise caution to protect any covered product or part from outside damage, adverse temperature (normal operating
ambient temperature 0 - 25°C), humidity conditions, fluctuations in the electrical system or physical abuse as well as failure related to workmanship in the installation of
the products or parts.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Installation
Remove the front diffuser from the base of the luminaire.
Select a suitable cable entry point.
Position and fix the base to a suitable solid surface.
Select the power setting you require by adjusting the dip switches on the LED Driver.
Terminate the supply cable into the terminal block mounted in the base, ensuring correct polarity is observed and the luminaire is earthed.
Installation of Emergency Luminaires – Additional Instructions to above
Connect as follows:-
For a switched Maintained operation, connect as above. For a continuous Maintained operation, install a continuous live to the permanent
live terminal and fit a link between live and permanent live.
Ensure the switch on the emergency kit it set to 'ON' (Please note: the emergency kit is switched off to ensure batteries do not completely
discharge during transport)
Re-fit the diffuser.
Restore power supply, switch on and test operation. A 24 hour period is required for battery to charge fully.
Warning
Failure to comply with these instructions may result in irreparable damage to the emergency control gear.
This product must not be modified in any way as this will negate any Safety approvals, and may render the product inoperable or unsafe.
The product must be installed in accordance with the instructions.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Page No. 1
Description – Eclipse LED with Self Test Emergency
Installation Instructions
Luminaire Code(s) –
C
PERMANENT LIVE
LIVE
NEUTRAL
EARTH
AECLED/M3
(L1)
BROWN OR RED (un-switched)
(L)
BROWN OR RED (switched)
(N)
BLUE OR BLACK
GREEN / YELLOW