DSC PG9929 Инструкции по установке
Просмотреть онлайн или скачать pdf Инструкции по установке для Система безопасности DSC PG9929. DSC PG9929 4 страницы. Wireless powerg series security 4 button panic key
D-304680
PG9929/PG8929/PG4929
PowerG Series 2-way Wireless key
Installation Instructions
Operation
Note: For UL Listed Product, Panic is for ancillary use only.
The PG9929/PG8929/PG4929 is a programmable four-button,
multi-LED, 2-way wireless key. The wireless key can be
configured to transmit up to five separate commands to the
alarm system. Four of the commands are transmitted by
pressing one of the buttons separately, and the fifth is by
pressing button 1 and 2 (as shown below) simultaneously.
Sending a command to the system causes the red LED to briefly
illuminate. If the system successfully acknowledges the
command the green LED briefly lights, then the associated blue
LED lights and the acknowledgment tone sounds. If the system
cannot perform the command the red LED briefly lights and the
error tone sounds. If the wireless key battery is low the yellow
LED blinks for 2 seconds. If there is a trouble on the system the
yellow LED lights for 2 seconds. If the system is armed and an
entry occurs, the DISARM LED blinks. The default
configuration of each button is as follows:
6
7
5
1
2
3
4
1. AWAY arm
2. STAY arm
3. DISARM
4. PANIC
5. Command Output 1 (buttons 1 and 2)
6. Message LED
7. Status LEDs
Device Setup
Enrollment
To quick enroll:
1. On a keypad press [*] [8] [Installer Code] [804] [000].
2. Press and hold the [*] button on the wireless key until the
LED lights steady and then release the [*] button while the
LED is still lit and a confirmation message appears on the
keypad.
3. Press [*] on the keypad to confirm the device ID.
4. Enter [3 digit wireless key #]
5. Assign the wireless key to a partition by entering the [three
digit partition #].
6.
To assign the wireless key to a user enter the [3 digit user #].
To pre-enroll:
1. Remotely configure the unique ID number into the system. For
more information see the HSM2HOST manual.
2. When on-site, press the [*] button on the wireless key.
Programming Buttons
To change button programming:
1. From a keypad enter [*] [8] [Installer Code] [804][601] to
[632].
2. Configure button 1 (Away Arm) using the table below. Enter the
desired two digit option.
3. Configure button 2 (Stay Arm) by entering the desired two digit
option and repeat for button 3 (Disarm), button 4 (Panic) and
button 5 (buttons 1 and 2 pressed simultaneously).
00
Disabled
16
Quick Exit
01
Disarm
17
Arm Interior
02
Instant Stay Arm
21
Comm. Output 1
03
Stay Arm
22
Comm. Output 2
04
Away Arm
23
Comm. Output 3
05
[*][9] No Entry
24
Comm. Output 4
06
Chime On/Off
29
Bypass Group Recall
07
System Test
30
Quick Bypass
09
Night Arm
33
Bypass Recall
11
Away Arm no Entry
36
Reactivate Stay/Away/
Night
12
Global Stay Arm
51
Aux. Alarm
13
Global Away Arm
52
Panic
14
Global Disarm
Configuration
To enter the wireless configuration section enter [804][601].
Device Toggles
[011][01]
Supervision - Default [N]
Enables supervision of the device.
Maintenance
Replacing the Battery
The required battery is CR2032 Lithium 3V, manufactured by
VARTA or Energizer, purchased from a DSC-approved
supplier.
When this wireless key is out of use, remove all batteries and
dispose of them separately. Bring electrical appliances to the
local collecting points for waste electrical and electronic
equipment. Batteries are harmful to the environment, Please
help to protect the environment from health risks.
Replace the battery at least once every 5 years, or upon
observing that the LED flickers when transmitting.
Note: The polarity of the battery must be observed. Improper
handling of lithium batteries may result in heat generation,
explosion or fire, which may lead to personal injuries.
Warning: Danger of explosion if batteries are installed
incorrectly. Replace only with the same or equivalent type
recommended by the manufacturer. Keep away from small
children. If batteries are swallowed, promptly see a doctor. Do
not try to recharge these batteries. Disposal of used batteries
must be made in accordance with the waste recovery and
recycling regulations in your area.
1. Remove backside screw and open the
cover.
2. Using a screwdriver, push out the
battery from its holder and install
new battery.
3. Reattach the cover and securely fas-
ten with screw.
4. Test the unit by pressing one of the
buttons. The LED should blink.
A. Button pad
B. LED indicator
C. Battery holder
D. Battery
Cleaning
The use of abrasives of any kind
and solvents such as kerosene, acetone or thinner is
strictly forbidden.
Clean the wireless key only with a soft cloth or sponge
moistened lightly with a mixture of water and mild detergent,
and wipe it dry immediately.
Testing
Always test the system at least once per a year.
1. Ensure the device is enrolled in the system.
2. Stand 3 m (10 ft) away from the control panel and press a but-
ton. Verify that the transmit LED lights and the control panel
responds as programmed.
3. Operate the wireless key from various locations within the area
covered by the receiver to determine "dead" locations, where
transmission is blocked by walls and large objects, or affected
by structural materials.
Note: If dead/marginal zones are a problem, relocating the
receiver may improve the performance.
Specifications
Frequency Band (MHz): CE Listed PG4929: 433-434MHz;
CE/EN listed PG8929: 868-869MHz; FCC/IC/UL/ULC listed
PG9929: 912-919MHz
Communication Protocol: PowerG
Battery type: For UL/ULC listed installation use only Varta or
Energizer 3V CR-2032 Lithium battery consumer grade
Battery Life Expectancy: 5 years
(not verified by UL/ULC)
Low Battery Threshold: 2.1 V
Note: If transmission is still possible despite the battery
condition, the unit will send a low battery signal to the control
panel.
Temperature range: -10ºC to +55ºC (UL only verified the
range 0º-49ºC)
Relative Humidity: up to max. 93%RH non-condensing
Dimensions (LxWxD): 67 x 27.6 x 12 mm (2.64 x 1.09 x 0.47
in.).
Weight (including battery): 25 g (0.9 oz).
Color: Black
Note: To be used in non-hazardous locations only.
Compatible Receivers
433MHz
Band:
HSM2HOST4;
HS2LCDRF(P)4;
HS2ICNRF(P)4; PG4920
868MHz
Band:
HSM2HOST8;
HS2LCDRF(P)8;
HS2ICNRF(P)8; PG8920
912-919MHz
Band:
HSM2HOST9;
HS2LCDRF(P)9;
HS2ICNRF(P)9; PG9920
Note: Only devices operating in band 912-919MHz are UL/ULC
listed.
UL/ULC Notes
Only model PG9929 operating in the frequency band 912-919MHz are
UL/ULC listed. The PG9929 has been listed by UL for commercial and
residential burglary applications and by ULC for residential burglary
applications.
Note: For UL commercial burglary applications:
•
After arming the system via the wireless key the user should ver-
ify the closing confirmation has been indicated at the keypad.
•
Panic button must be disabled.
For UL/ULC installations use this device only in conjunction with
compatible DSC wireless receivers: HSM2HOST9, HS2LCDRF(P)9,
HS2ICNRF(P)9 and PG9920. After installation verify the product
functionality in conjunction with the compatible receiver used.
Europe: The PG4929 and PG8929 are compliant with the RTTE requirements -
Directive 1999/5/EC of the European Parliament and of the Council of 9 March
1999. The PG8929 is certified by DNV (DET NORSKE VERITAS) to the
following standards: EN50131-3, EN50131-1 GRADE 2, CLASS II, EN50131-6
Type C. DNV (DET NORSKE VERITAS) has certified only the 868 MHz variant of this product.
According to EN 50131-1:2006 and A1:2009, this equipment can be applied in installed systems up
to and including Security Grade 2, Environmental Class II. UK: The PG8929 is suitable for use in
systems installed to conform to PD6662:2010 at Grade 2 and environmental class 2. BS8243 The
Power G peripheral devices have two- way communication functionality, providing additional
benefits as described in the technical brochure. This functionality has not been tested to comply with
the respective technical requirements and should therefore be considered outside the scope of the
product's certification
FCC COMPLIANCE STATEMENT
WARNING! Changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in residential installations. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this
device does cause such interference, which can be verified by turning the device off and on, the user
is encouraged to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies power to the
receiver.
– Consult the dealer or an experienced radio/TV technician.
This equipment complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled
environment.
This device complies with FCC Rules Part 15 and with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference that may be received or that
may cause undesired operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
PG9929/PG8929/PG4929
Instructions d'installation de la clé sans fil
bidirectionnelle PowerG
Fonctionnement
Remarque : Pour les produits référencés UL, la fonction
Demande d'aide est prévue uniquement pour une utilisation
accessoire.
Les clés PG9929/PG8929/PG4929 sont des clés sans fil
bidirectionnelles, à quatre boutons programmables, munies de
plusieurs voyants. La clé sans fil peut être configurée pour
transmettre jusqu'à cinq commandes distinctes au système
d'alarme. Quatre des commandes sont transmises en appuyant
séparément sur les boutons, et la cinquième est transmise en
appuyant simultanément sur les boutons 1 et 2 (comme illustré
ci-dessous). L'envoi d'une commande au système produit
l'illumination brève du voyant lumineux rouge. Si le système
exécute avec succès la commande, le voyant lumineux vert
s'allume brièvement, puis le voyant lumineux bleu associé,
enfin une tonalité de confirmation retentit. Si le système n'est
pas en mesure d'exécuter la commande, le voyant lumineux
rouge s'allume brièvement et une tonalité d'erreur retentit. Si le
niveau de pile de la clé sans fil est faible, le voyant lumineux
jaune clignote pendant 2 secondes. Si un incident est présent
sur le système, le voyant lumineux jaune s'allume pendant 2
secondes. Si le système est armé et une entrée se produit, le
désarmer voyant clignote. La configuration par défaut pour
chaque bouton est la suivante :
6
7
5
1
2
3
4
1. Armer en mode d'absence
2. Armer en mode à domicile
3. Désarmer
4. De demande d'aide
5. Sortie de commande 1 (boutons 1 et 2)
6. Voyant de message
7. Voyant d'état
Réglage du dispositif
Attribution
Pour une attribution rapide :
1. Sur un clavier, appuyez sur [*] [8] [Code de l'installateur]
[804] [000].
2. Appuyez et maintenez la touche [*] sur la clé sans fil jusqu'à ce
que la LED s'allume stable et puis relâchez le bouton [*]
pendant que le voyant est toujours allumé et un message de
confirmation apparaît sur le clavier.
3. Appuyez sur [*] sur le clavier pour confirmer l'ID de l'appareil.
4. Entrez [3 chiffres sans clé #].
5. Attribuez la clé sans fil à une partition en entrant le [trois
chiffres partition #].
6. Pour attribuer la clé sans fil à un utilisateur d'entrer le [3 chiffres
utilisateur #].
Pour une attribution préalable :
1. Configurez à distance le numéro ID unique dans le système.
Pour plus d'informations, consultez le manuel HSM2HOST.
2. Sur site, appuyez sur le bouton [*] de la clé sans fil.
Boutons de programmation
Pour changer la programmation des boutons :
1. Depuis le pavé numérique, entrez la commande [*] [8] [Code de
l'installateur] [804][601] à [632].
2. Configurez le bouton 1 (Armer en mode absence) en utilisant le
tableau ci-dessous. Entrez l'option à deux chiffres souhaitée.
3. Configurez le bouton 2 (Armement à domicile) en entrant les
deux chiffres de l'option souhaitée et répétez cette opération
pour les boutons 4 (Désarmement), 4 (Demande d'aide) et 5 (les
deux boutons 1 et 2 appuyés simultanément).
00
Désactivé
16
Sortie rapide
01
Désarmer
17
Armement en intérieur
02
Armer en mode à
21
Communication Sortie 1
domicile à effet
instantané
03
Armer en mode à
22
Communication Sortie 2
domicile
04
Armer en mode
23
Communication Sortie 3
d'absence
05
[*][9] Sans entrée
24
Communication Sortie 4
06
Carillon Activé/
29
Rappel de groupe de
Désactivé
suspension
07
Essai du système
30
Suspension rapide
09
Armer en mode nuit
33
Rappel de suspension
11
Armer en mode absence
36
Réactiver en mode à
sans entrée
domicile/absence/nuit
12
Armer globalement en
51
Alarme Alarme
mode à domicile
13
Armer globalement en
52
De demande d'aide
mode absence
14
Désarmer globalement
Configuration
Pour accéder à la section de configuration sans fil, entrez la
commande [804][601].
Commutateurs du dispositif
[011][01]
Supervision : Valeur par défaut [O]
Active la supervision
Maintenance
Remplacement de la pile
La pile nécessaire est une pile CR2032 au lithium de 3 V,
fabriquée par VARTA ou Energizer, achetée auprès d'un
fournisseur agréé DSC.
Lorsque cette clé sans fil est hors d'usage, retirez toutes les piles
et de les éliminer séparément. Amenez les appareils électriques
aux points de collecte de traitement des équipements
électroniques et électriques usagés. Les piles sont dangereuses
pour
l'environnement,
veuillez
contribuer
à
protéger
l'environnement pour prévenir des risques sur la santé.
Remplacez la pile au moins une fois tous les 5 ans ou en
fonction de la faiblesse des voyants lumineux lors de la
transmission.
Remarque : Respectez la polarité de la pile. La manipulation
incorrecte des piles au lithium peut engendrer une production
de chaleur, une explosion ou un incendie, qui peuvent
provoquer des blessures personnelles.
Avertissement : Danger d'explosion si les piles sont installées
de façon incorrecte. Remplacez uniquement les piles par des
piles identiques ou équivalentes, recommandées par le
fabricant. Gardez-les hors de portée des enfants en bas âge. Si
les piles sont avalées, consultez immédiatement un médecin.
N'essayez pas de recharger ces piles. L'élimination des piles
usagées doit être réalisée conformément aux réglementations
du recyclage et de la récupération des déchets en vigueur dans
votre région.
1. Retirez la vis à l'arrière et ouvrez le
couvercle.
2. À l'aide d'un tournevis, retirez la pile
de son logement et installez une pile
neuve.
3. Remontez le couvercle et serrez bien
la vis.
4. Testez le dispositif en appuyant sur
l'un des boutons. Le voyant
lumineux doit clignoter.
A. Pavé de boutons
B. Indicateur lumineux
C. Logement de la pile
D. Batterie