DAITEM SH423AX Руководство по установке - Страница 7

Просмотреть онлайн или скачать pdf Руководство по установке для Система безопасности DAITEM SH423AX. DAITEM SH423AX 13 страниц. Siren external

4.16 Allocation of siren to alarm group
To allocate the siren to one or several alarm system groups, enter:
siren n°
Factory setting: all groups
Example, to allocate siren n° 1 to Group 2 and Group 3, enter:
4.17 Type of indication
4.17.1 For warnings
To modify the type of warning indication, enter:
siren n°
Factory setting: 3
4.17.2 For deterrence
To modify the type of deterrence indication, enter:
siren n°
Factory setting: 2
4.17.3 For prealarms
To modify the type of prealarm indication, enter:
siren n°
Factory setting: 2

4.18 Anti-tamper switch triggering

To modify the conditions under which the anti-tamper switch will activate the siren, enter:
siren n°
Factory setting: 1
4.19 Checking
To check parameter-setting, enter:
siren n°
parameter
Example, to check on siren n° 1, parameter 4: duration of sounding, enter
...
groups from 1 to 8 depending
on the type of control panel
0: disabled
1: sounding (2 s)
2: sounding (2s) and flashing (5 s)
3: flashing (5 s)
0: disabled
1: sounding (5 s)
2: sounding (5 s) and flashing (5 s)
3: flashing (5 s)
0: disabled
1: sounding (loud for 15 s)
2: sounding (loud for 15 s) and flashing (15 s)
3: flashing (15 s)
0: enabled 24 h/day
1: enabled if system totally armed
"4, bip, 9, 0"
7