DSC WLS904-433 Инструкции по установке - Страница 3

Просмотреть онлайн или скачать pdf Инструкции по установке для Датчики безопасности DSC WLS904-433. DSC WLS904-433 4 страницы. Wireless motion

Changing the Motion Detector Sensitivity
The motion detector features Fast and Slow detection
modes, which are set on jumper J1. Jumper J1 is set at the
factory for the Fast detection mode. In a normal operating
environment, this setting provides the best detection.
In certain environments where rapid air movement,
heaters and other variables present problems, use Slow
detection mode to stabilize the detection.
Jumper "J1" is located in the bottom right corner of the
circuit board. To change the setting from Fast to Slow,
move the jumper over one pin, as shown in the diagram.
High Traffic Shutdown Mode
To prolong battery life, the motion detector uses a feature called High Traffic
Shutdown. When motion is detected, the device will transmit to the receiver
and will then shut down for six minutes. If motion is detected again during the
first six minute shutdown time, the unit will reset the shutdown timer to three
minutes. Each time the detector is tripped during the shutdown time, the timer
will be reset to three minutes again. The detector will thus remain in the shut
down mode until it does not detect motion for an entire six minute period.
The High Traffic Shutdown Mode affects testing the motion detector in two ways:
• When performing the module placement test, you must tamper the unit.
To do this, remove the detector from the backplate and then replace it.
Once the detector is replaced on the backplate the panel will show and/
or sound the result of the placement test at the keypad.
• When performing a system test, the unit must be left idle for six minutes
before testing can be performed. Once six minutes has passed, create
motion in front of the detector to see if the device is both detecting motion
and transmitting to the receiver.
Motion Detector Transmission Delay
A motion detector transmission is always delayed by five seconds. This is
necessary to prevent false alarms caused by a motion sensor transmitting
before a delay zone has a chance to report. This five-second delay cannot
be altered or disabled.
Walk Test Mode
The motion detector has a walk test mode which will activate an LED for
testing purposes. During normal operation, the LED will not turn on.
To put the detector in walk test mode, create a tamper by removing the
detector from its backplate and then replacing it. Each time the detector
senses motion, it will turn on the red LED. Five seconds after motion is
detected, the detector will send a signal to the receiver, and the LED will
flash rapidly 5 times. The detector will be in walk test mode until it has sent
10 transmissions.
NOTE: The Walk Test Mode will override the High Traffic Shutdown Mode.