DSC TL280R Руководство по установке - Страница 7
Просмотреть онлайн или скачать pdf Руководство по установке для Сотовый телефон DSC TL280R. DSC TL280R 16 страниц. Internet alarm communicator - international
Также для DSC TL280R: Руководства по установке (17 страниц), Руководство по установке (16 страниц)
Installing Ethernet Communicator in Panel
d. Attach the other end of the PC-LINK cable to the communicator (red wire goes on the right-
hand pin of the communicator PC-LINK header (see Figure 3)).
e. Using light pressure (finger tight only), attach the supplied white quad band whip antenna to
the threaded antenna connection point at top of the panel.
WARNING! - Modules are power limited. Do not route any wiring over the circuit board.
Maintain at least 1in. (25.4mm) separation between circuit board and wiring. A minimum
of ¼ in. (7mm) separation must be maintained at all points between non-power limited
wiring and power limited wiring.
3. To electrically connect the communicator to the panel, perform the following steps (see Figure 3).
a. Disconnect both AC power and battery connections from the panel, and disconnect tele-
phone line.
Figure 3: Communicator Wiring Diagram
Input Ratings:
+10.8V ~ +12.5 VDC
100mA
DSC Panel min. power requirements:
- 16.5 VAC 40 VA transformer;
- 12 VDC 7Ah battery
HS2016/2032/2064/2128
AC AC
AUX+
4. Install the RS-422 connections (R models only). When installing the communicator for use
with 3rd party applications an RS-422 cable must be connected between the 3rd party device
and the communicator module. Maximum cable length for RS-422 cable is 1,000 ft. (305 m).
NOTE: Please refer to the installation manual for the 3rd party device for wiring instructions.
Wire the RS-422 connections as per the table below:
NOTE: The GND connection is optional. DSC recommends connecting GND wire at both ends.
Install Network Cable
1. Route the CAT 5 Ethernet cable through back of the panel and plug it into the communicator's
RJ45 jack.
2. Perform the following steps for initial power on of the panel with communicator installed:
a. Reconnect the AC power, telephone line, and battery + connector to the panel.
(The communicator and panel will power up together).
b. Observe that the communicator's red and yellow LEDs are flashing together while it initial-
izes. The red and yellow LEDs will continue to flash until the communicator has success-
PCLINK_2
UA621
RS-422
To 3rd party device
PGM1
PGM3
Z1 COM Z2 Z3 COM Z4 Z5 COM
PGM2
PGM4
Table 3: RS-422 Connections
3rd Party Device
TX+
TX-
RX+
RX-
GND (Optional)
Internet Alarm Communicator Installation Guide
TL280(R)
DSC
UA601
PC-LINK
Red
Red
Z6 Z7 COM Z8
RING
TIP
T-1
R-1
Communicator
RX+
RX-
TX+
TX-
GND
4
1
AUDIO/DEFAULT
Jumper pins 4 and 5
to reset.
Network Link
YELLOW
RJ-45
COM
From NID
TL2803G(R)
Use only CAT5
Supervised
Maximum cable length
100 m (328 ft)