• Batteries: Refer to the Batteries section for details
• Operating Temperature Range: 60° to 80°F
• Weight: 3.1 oz. (with batteries and without mounting accessories)
• Dimensions: 3.1'' h x 1.8'' w x 2.3'' d
• Supervisory Interval: 100 minutes (sensor), 3 hours (alarm hardwire)
• Wireless Signal Range: Greater than 400 ft open air
• Color: White
• Recommended Mounting Height and Angle: Refer to the Recommended Install Height and Angle Table
• Motion Profiles & Sensor Range: Refer to the PIR Sensitivity Settings Table
HARDWARE COMPATIBILITY REQUIREMENTS – By Panel
Panel
Impassa
PowerSeries Neo

OTHER FEATURE COMPATIBILITY

Two-Way Voice Compatibility - Images cannot be transmitted while a Two-Way Voice call is in session. When the
Image Sensor is installed on a system with Two-Way Voice over the cellular network, image transmission during an
alarm may be interrupted by the two-way session. The image transmission resumes once the call has terminated.

PET IMMUNITY SETTINGS

Two parts to making the Image Sensor pet immune:
1. Set PIR sensitivity settings to "low",
2. Mount set at a height of 6 ft, and install the sensor with the 6 degree mounting angle.
BATTERIES
Battery type: The Image Sensor uses 2 AA 1.5v Energizer Ultimate Lithium batteries (UL compliant).
Expected Battery Life: Approximately 4 years with lithium batteries.
Voltage Thresholds: With lithium batteries, low battery alerts are issued at 3.05V. The sensor cannot operate when the
voltage reads below 2.30V.
Low Battery Notification: Panel will display a low battery alert for the sensor and/or notifications are issued via the
Alarm.com platform if the customer has subscribed to this notification type.
https://answers.alarm.com/Installation_and_Troubleshooting/Image_Sensor/DSC_PowerSeries_Neo_Image_Sensor/DSC_PowerSeries_
Panel Version
V1.3+
V1.0+
Module Firmware
Alarm.com SKU
Alarm.com SKU
Extra Hardware
3G8055(I) or CD8055(I)
SKU 3G8080(I) or
CD8080(I)
Updated: Tue, 17 Apr 2018 13:46:31 GMT