UNICABLE REPAIR / REPLACEMENT
STEP #1
Remove liner from gun (See Section 2.5 LINER REPLACEMENT).
Mount neck in vise.
Remove housing screws and slide housing back (front and back).
Loosen connector cone from neck using 1" (25 mm) wrench.
Remove from vise and thread out neck by hand.
Cable connection between cone and crimp ring should not be disturbed.
Unthread power pin and remove using 1 1/4" (32 mm) on connector cone and a 5/8" (16
or 3/4" (19 mm) wrench on power pin. Install new power pin.
Retrieve front and rear housing. Slide housings onto new unicable assembly.
Repeat procedure in reverse to assemble remaining components.