Absolute Process Instruments API 6380 G Series Краткое руководство по эксплуатации

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Передатчик Absolute Process Instruments API 6380 G Series. Absolute Process Instruments API 6380 G Series 2 страницы. Ac to dc transmitters, isolated, field rangeable

Absolute Process Instruments API 6380 G Series Краткое руководство по эксплуатации
AC to DC Transmitters, Isolated, Field Rangeable
Input:
0-50 mVAC to 0-250 VAC, 0-5 mAAC to 0-200 mAAC
Output:
0-1 VDC to ±10 VDC, 0-2 mADC to 0-20 mADC
O One Minute Setup for Hundreds of I/O Ranges
O External Switches & Tables for Range Selection
O Non-Interactive Zero and Span Calibration
O Full 2000 V Input/Output/Power Isolation
O Input and Output LoopTracker
LEDs
®
O Output Test Button
O Built-In Loop Power Supply for mA Output
Applications
Q Convert AC Signals to DC Process Signals
Q Monitor Line Voltage or Current Levels
Q Isolate and Convert AC Signals for Panel Meters, PLCs,
Recorders, Data Acquisition, DCS, & SCADA Systems
AC Input Ranges
Field selectable ranges via switch settings
System voltages must not exceed socket voltage rating
Voltage:
0-50 mVAC
to 0-250 VAC
Current:
0-5 mAAC
to 0-200 mAAC
S option:
True RMS input measurement
See API 6380 G 5A for current input ranges up to 0-5 AAC
Input Impedance
Voltage (0-4 VAC):
1 MΩ minimum
Voltage (>4 VAC): 220 kΩ minimum
10 Ω typical
Current:
Input Frequency
40 Hz to 1000 Hz sinusoidal
Input Protection, Common Mode
750 VDC or 750 VACp
LoopTracker
Variable brightness LEDs indicate I/O loop level and status
DC Output Ranges
Field selectable ranges via switch settings
Voltage:
0-1 VDC
to 0-10 VDC
Bipolar Voltage:
±1 VDC
to ±10 VDC
Current:
0-2 mADC
to 0-20 mADC
20 V compliance, 1000 Ω at 20 mA
Output Logic
Normal acting, internal jumper for output reversal
Output Calibration
Multi-turn zero and span potentiometers for output
±15% of span adjustment range typical
Output Loop Power Supply
20 VDC nominal, regulated, 25 mADC, max. ripple <10 mV
Output Test
Front button sets output to test level when pressed
Potentiometer adjustable 0-100% of span
Output Ripple and Noise
Less than 10 mV
RMS
Linearity
Better than ±0.1% of span
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than ±0.02% of span per °C stability
Response Time
200 milliseconds typical (0-90%)
Isolation
2000 V
minimum
RMS
Full isolation: power to input, power to output, input to output
Installation Environment
IP 40, requires installation in panel or enclosure
Use with API 008 or API 008 FS socket
Socket mounts to 35 mm DIN rail or can be surface mounted
UL 508C pollution degree 2 environments or better
Power
Standard:
115 VAC ±10%, 50/60 Hz, 2.5 W max.
P option:
85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W
A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.
D option:
9-30 VDC, 2.5 W typical
A
P
BSOLUTE
ROCESS
Variable Brightness
Input LED
Output Test Button
Output Test Adjust
Output Span
Output Zero
Variable Brightness
Output LED
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
Free Factory
I/O Setup!
Description
The API 6380 G accepts an AC voltage or current input and pro-
vides an optically isolated DC voltage or current output that is
linearly related to the input. Accuracy is maintained over a wide
frequency range for maximum flexibility. A true RMS model API
6380 G S is available for distorted AC inputs.
The full 3-way (input, output, power) isolation makes this mod-
ule useful for ground loop elimination, common mode signal
rejection or noise pickup reduction.
20 input and 16 output ranges can be field-configured via
RMS
external rotary and slide switches. Popular ranges are listed
on the module label. Consult the factory for assistance with
special ranges.
Model
API 6380 G
API 6380 G A230
API 6380 G P
0-5 mAAC to 0-200 mAAC
API 6380 G D
API 6380 G S
API 6380 G A230 S
True RMS input measurement
API 6380 G P S
0-5 mAAC to 0-200 mAAC
API 6380 G D S
Free Factory Setup
Specify I/O ranges if factory is to set switches
Option—add to end of model number
U
Conformal coating for moisture resistance
Accessories—order as a separate line item
API 008
8-pin socket, DIN rail or surface mount
API 008 FS 8-pin finger safe socket, DIN rail or surface mount
API CLP1
Module hold-down spring for high vibration or
mobile applications
I
NSTRUMENTS
2.38"
1.75"
Hot Swappable
Plug-In Design
LoopTracker
API exclusive features include two LoopTracker LEDs (green for
input, red for output) that vary in intensity with changes in the
process input and output signals. These provide a quick visual
picture of your process loop at all times and can greatly aid in
saving time during initial startup and/or troubleshooting.
Output Test
An API exclusive feature includes the test button to provide a
fixed output (independent of the input) when held depressed.
The test output level is potentiometer adjustable from 0 to
100% of output span.
The output test button greatly aids in saving time during initial
startup and/or troubleshooting.
Input
Field configurable
0-1 VDC to 0-10 VDC
0-50 mVAC to 0-250 VAC
0-2 mADC to 0-20 mADC
Field configurable
0-1 VDC to 0-10 VDC
0-50 mVAC to 0-250 VAC
0-2 mADC to 0-20 mADC
300 V Rating
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
Fax: 800-949-7502
API 6380 G Series
Socket Sold
Separately
115 VAC, 230 VAC models
with input up to 150 VAC
E145968
1
Minute
Setup!
Quick Link
api-usa.com/6380
Output
Module Power
115 VAC
Field configurable
230 VAC
±1 VDC to ±10 VDC
85-265 VAC or 60-300 VDC
9-30 VDC
115 VAC
Field configurable
230 VAC
±1 VDC to ±10 VDC
85-265 VAC or 60-300 VDC
9-30 VDC
API 008 FS
API 008
600 V Rating
api-usa.com
2.75"
API CLP1
© 08-19