Absolute Process Instruments Cecomp F16LSC Инструкции - Страница 2
Просмотреть онлайн или скачать pdf Инструкции для Передатчик Absolute Process Instruments Cecomp F16LSC. Absolute Process Instruments Cecomp F16LSC 4 страницы. 2-wire loop powered digital pressure transmitters with display backup
Instructions
Dimensions
Low loop
voltage
indicator
Select Test
Non-metallic system installations
require connecting gauge sensor to
earth ground to avoid static elec-
tricity damage to gauge.
Ranges and Selectable Units
Range Codes
T
he gauge model range code indicates the default range. Alternate
default engineering units may be ordered.
Sensor Range
psi
kPa
and Units
–14.7 to
–101.3 to
–14.7 to 15.0 psig
15.0
103.4
–29.9 inHg to
–14.7 to
–101.3 to
15.0 psig
15.0
103.4
–29.9 inHg to
–14.7 to
–101 to
100.0 psig
100.0
690
–29.9 inHg to
–14.7 to
–101 to
200.0 psig
200.0
1379
0 to 3.000 psig
3.000
20.68
0 to 5.000 psig
5.000
34.47
15.00 to 0 psi abs
15.00 abs 103.4 abs .1034 abs 1034 abs 1.034 abs 1.021 abs 1.055 abs 1055 abs
0 to 14.70 psig vac 14.70 vac 101.3 vac .1013 vac 1013 vac 1.013 vac 1.000 vac 1.033 vac 1033 vac
0 to 15.00 psig
15.00
103.4
30.00 to 0 psi abs
30.00 abs 206.8 abs .2068 abs 2068 abs 2.068 abs 2.041 abs 2.109 abs 2109 abs
0 to 30.00 psig
30.00
206.8
0 to 60.00 psig
60.00
413.7
100.0 to 0 psi abs
100.0 abs 689.5 abs .6895 abs 6895 abs 6.895 abs 6.805 abs 7.031 abs 7031 abs
0 to 100.0 psig
100.0
689.5
0 to 200.0 psig
200.0
1379
0 to 300.0 psig
300.0
2068
0 to 500.0 psig
500.0
3447
0 to 1000 psig
1000
6895
0 to 3000 psig
3000
0 to 5000 psig
5000
Installation Precautions
4 Read these instructions before using the gauge. Configuration may
be easier before installation. Contact the factory for assistance.
4 These products do not contain user-serviceable parts. Contact us
for repairs, service, or refurbishment.
4 Gauges must be operated within specified ambient temperature ranges.
4 Outdoor or wash down applications require a NEMA 4X gauge or
installation in a NEMA 4X housing.
4 Use a pressure or vacuum range appropriate for the application.
4 Use fittings appropriate for the pressure range of the gauge.
4 Due to the hardness of 316 stainless steel, it is recommended that
a thread sealant be used to ensure leak-free operation.
4 For contaminated media use an appropriate screen or filter to
keep debris out of gauge port.
4 Remove system pressures before removing or installing gauge.
4 Install or remove gauge using a wrench on the hex fitting only. Do
not attempt to turn gauge by forcing the housing.
4 Good design practice dictates that positive displacement liquid
pumps include protection devices to prevent sensor damage from
pressure spikes, acceleration head, and vacuum extremes.
p Avoid permanent sensor damage! Do not apply vacuum to non-
vacuum gauges or hydraulic vacuum to any gauges.
p Avoid permanent sensor damage! NEVER insert objects into
gauge port or blow out with compressed air.
Gauges are not for oxygen service. Accidental rupture of sensor
diaphragm may cause silicone oil inside sensor to react with
oxygen.
p NEVER connect the gauge wires directly to 115 VAC or perma-
nent damage will result.
C E C OMP
Div. of
Numeric display
Alpha-numeric
display
88888
X X X X X
2
Up Down
SEL
TEST
s
t
Loop-Tracker
Red LED
Cecomp Electronics / Made in USA
0.75"
¼" NPT
3.38" Standard
3.5" NEMA 4X
Selectable Ranges
Engineering units may be changed to any of those listed in the same
row as shown in the table below.
MPa
mbar
bar
atm
–.1013 to
–1013 to
–1.013 to
–1.000 to
.1034
1034
1.034
1.021
–.1013 to
–1013 to
–1.013 to
–1.000 to
.1034
1034
1.034
1.021
–.101 to
–1.01 to
–1.00 to
.690
6.90
6.81
–.101 to
–1.01 to
–1.00 to
1.379
13.79
13.61
206.8
.2068
.2041
344.7
.3447
.3402
.1034
1034
1.034
1.021
.2068
2068
2.068
2.041
.4137
4137
4.137
4.083
.6895
6895
6.895
6.805
1.379
13.79
13.61
2.068
20.68
20.41
3.447
34.47
34.02
6.895
68.95
68.05
20.68
206.8
204.1
34.47
344.7
340.2
Cecomp maintains a constant effort to upgrade and improve its products.
Specifications are subject to change without notice. See cecomp.com for
latest product information. Consult factory for your specific requirements.
WARNING: This product can expose you to chemicals including
nickel and chromium, which are known to the State of Califor-
nia to cause cancer or birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
Electrical Connection
All operating power is supplied by the 4-20 mA current loop using
the 2-wire cable at the gauge rear. The F16LSC can be used as
an indicating transmitter in any 4-20 mA current loop or as a DC
powered gauge. Reversing the connections will not harm the gauge
but it will not operate with incorrect polarity.
Select a loop power supply voltage and total loop resistance so that
when the loop current is 20 mA, the gauge will have at least 10 VDC
at its terminals but not over 32 VDC.
For correct operation and to avoid erratic or erroneous readings, the
gauge terminal voltage must not fall below 10 VDC. Too large a loop
resistance will cause the gauge output to "limit" or saturate before
reaching its full 20 mA output. The minimum loop supply voltage
may be calculated from the formula:
V
= 10V + (20mA x Total loop resistance)
min
RED +
BLACK –
mA meter (–)
mA meter (+)
To use the transmitter as a low
voltage powered gauge connect it
to any 10-32 VDC power supply.
A
P
BSOLUTE
ROCESS
2.88"
1.65"
kg/cm
2
g/cm
2
mmH
O cmH
2
–1.033 to
–1033 to
–1033 to
1.055
1055
1055
–1.033 to
–1033 to
–1033 to
1.055
1055
1055
–1.03 to
7.03
–1.03 to
14.06
.2109
210.9
2109
210.9
.3515
351.5
3515
351.5
1055 abs 240.0 abs 34.61 abs 415.1 abs 775.7 abs 775.7 abs 30.54 abs
1033 vac 235.1 vac 33.90 vac 406.8 vac 760 vac
1.055
1055
1055
2109 abs 480.0 abs 69.21 abs 830 abs
2.109
2109
2109
4.218
4218
4218
7031 abs 1600 abs 230.7 abs 2767 abs 5171 abs 5171 abs 203.6 abs
7.031
7031
7031
14.06
21.09
35.15
70.31
210.9
351.5
Power (+)
BLACK –
Power (–)
Power (–)
RED +
Power (+)
- or -
mA meter (+)
mA meter (–)
BLACK –
Power (–)
RED +
Power (+)
1220 American Way Libertyville, IL 60048
I
NSTRUMENTS
F16LSC, F16LSCN
3 ft long,
3 ft long,
3.0"
2-conductor
2-conductor
22 AWG
22 AWG
NEMA 4X
cable
cable
Allow 1"
Allow 1"
clearance
clearance
Turn at hex
Turn at hex
fitting
fitting
only!
only!
2.0"
Conversion
Engineering unit conversions are calculated from the factory default
unit to the newly selected units.
O
oz/in
2
ftH
O
inH
O
mmHg
2
2
2
–235.1 to
–33.90 to
–407 to
–760 to
240.0
34.61
415
776
–235.1 to
–33.90 to
–407 to
–760 to
240.0
34.61
415
776
–235 to
–33.9 to
–407 to
–760 to
1600
230.7
2767
5171
–235 to
–33.9 to
–407 to
3200
461.4
5534
48.00
6.921
83.0
155.1
80.0
11.54
138.4
258.6
240.0
34.61
415.1
775.7
1551 abs 1551 abs 61.08 abs
480.0
69.21
830
1551
960
138.4
1660
3103
1600
230.7
2767
5171
3200
461.4
5534
4800
692.1
1154
2307
6921
Normal Operation
The F16LSC is designed for continuous operation. Warm-up time
is negligible.
When loop power is applied, the gauge will power-up automati-
cally. All active display segments are turned on for approximately
1 second.
After initialization, the gauge will begin operating in the Normal
Mode. The display will show the applied pressure. The loop cur-
rent and the Loop-Tracker
LED brightness will correspond to the
®
applied pressure.
The output is a 12,000 count analog 4-20 mA signal. The output
is filtered to improve noise immunity and is updated approximately
16 times per second.
Zero Tare, Push-To-Test, Configuration and Calibration modes are
accessible from the Normal Mode.
The power supply for the Backup Power mode recharges during
Normal Mode operation.
It takes approximately two hours of operation in the Normal Mode to
fully charge the backup power supply from the loop supply.
If loop power is lost, the gauge will automatically switch to the
Backup Power mode and continue to display the applied pressure
for 15 seconds.
Below are the 4-20 mA output values for various types of sensors,
assuming the output scale has not been adjusted.
Sensor Range
vacuum
Gauge reference pressure
Gauge reference vacuum
20 mA
Compound –30inHg/15psi
4 mA
Compound –30inHg/100psi
4 mA
Compound –30inHg/200psi
4 mA
Absolute reference
4 mA
Bipolar ±
4 mA
cecomp.com
800-942-0315
torr
inHg
–760 to
–29.92 to
776
30.54
–760 to
–29.92 to
776
30.54
–760 to
–29.9 to
5171
203.6
–29.9 to
407.2
155.1
6.108
258.6
10.18
760 vac
29.92 vac
775.7
30.54
1551
61.08
3103
122.2
5171
203.6
407.2
610.8
1018
2036
6108
Full
"0" on
Full
display
pressure
n/a
4 mA
20 mA
4 mA
n/a
12 mA
20 mA
5.5 mA
20 mA
4.8 mA
20 mA
4 mA
20 mA
12 mA
20 mA