Attwood 6143 Инструкции по монтажу - Страница 2

Просмотреть онлайн или скачать pdf Инструкции по монтажу для Водяной насос Attwood 6143. Attwood 6143 2 страницы. 2-way faucet/hand pump

ATTWOOD 6143
2-WAY FAUCET
30-40 PSI
PRESSURE
LIMITING
VALVE
CITY WATER
CONNECTION
OPERATING INSTRUCTIONS:
When connected to city water pressure, turn knob on faucet to
start/stop water flow. When shutting off water be careful not to
overtighten.
To use faucet as a hand pump completely unscrew the knob,
then operate by pumping up and down to draw fresh water
from supply tank. When finished, push knob down until bottom
of stroke is reached. Turn knob clockwise until tight, once
again being careful not to overtighten.
TROUBLE SHOOTING:
PROBLEM
Water will not turn on
Water will not shut off
Pump will not maintain
a prime
Pump leaking at top
Pump leaking at water
connection
Flapper valve needs
frequent replacement
MAINTENANCE:
Faucet should be drained during the winter months when not
in use.
Drain storage tank through water connection hose. If hose is
inaccessible then tank should be pumped and a non-toxic
antifreeze added and circulated according to its manufacturers
instructions.
Clean faucet using a non-abrasive household cleaner, mild
soap, or detergent.
© 2003 Attwood Corporation
1016 N. Monroe Street, Lowell, MI 49331-0260
CHECK TEE
VALVE
WATER SUPPLY TANK
FIGURE 2
CAUSE
1. line is plugged
2. line is broken
3. no water in supply tank
4. lower seal worn out
5. lower seal improperly installed
6. flapper valve is defective
7. disk improperly installed
1. flapper valve is defective
2. flapper valve is held open by
an obstruction
3. flapper valve missing
1. flapper valve defective
2. flapper valve missing
1. seal is worn out
2. seal is improperly installed
1. hose clamp missing
2. hose clamp loose
3. pipe connection loose
1. disk missing
www.attwoodmarine.com