3onedata IES5028G-4GS-8GC Руководство по быстрой установке - Страница 2

Просмотреть онлайн или скачать pdf Руководство по быстрой установке для Переключатель 3onedata IES5028G-4GS-8GC. 3onedata IES5028G-4GS-8GC 3 страницы. Industrial layer 2 ethernet switch
Также для 3onedata IES5028G-4GS-8GC: Руководство по быстрой установке (3 страниц)

3onedata IES5028G-4GS-8GC Руководство по быстрой установке
Step 4
Check and confirm the product is firmly installed on
the rack, then mounting ends.
【Disassembling Device】
Step 1
Power off device.
Step 2
Adopt screw driver to loosen the 4 bolts fixed on
the mounting lugs in the rack.
Step 3
Remove
the
device
away
disassembling ends.
【Power Supply Connection】
This device provides 2 AC power supply access
interfaces which come with a switch. The power
supply input range is 100~240VAC/DC.
Note:
Power ON operation: First insert the power supply terminal
block into the device power supply interface, and then plug
the power supply socket and power on.
Power switch "—" means power ON, "O" means power OFF.
Power OFF operation: First, put the powers switch to the "O"
side and then disconnect the power supply. Finally disconnect
the connector between the device and the power cord. Please
notice the operation order above.
【Restoring Default Settings】
RESET is restoring default settings button. Restoring default
settings steps as follows: Press and hold the RESET button,
disconnect the power supply and then power on the device,
wait for about 3~4 seconds to restore the factory settings.
【Relay Connection】
R+ and R- are the relay alarm output
section. They are open circuit in normal non alarm state,
closed when any alarm information occurs. The product
supports 2-way relay alarm output, externally connected to
alarm lights or alarm buzzer or other switching value
collecting device in order to timely notify operators when the
alarm occurs.
【Console Port Connection】
The series products provide 1 program debugging port
based on RS-232 serial port which can conduct device CLI
command management after connecting to PC. It adopts
RJ45 interface, its pin definition is showed as follows:
Pin No.
from
the
rack,
Definition
【Checking LED Indicator】
The series products provide LED indicators to monitor the
device working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
State
ON
P1
OFF
ON
P2
OFF
Blinking
OFF
RUN
ON
ON
ALM
OFF
Link
ON
2
3
5
TXD
RXD
GND
Description
Power supply is connected or
running normally
Power supply is disconnected or
running abnormally
Power supply is connected or
running normally
Power supply is disconnected or
running abnormally
System is running normally
System is not running or running
abnormally
System is running abnormally
Power supply or the port's link is
alarming.
Power and the port's link exist no
alarm
Port connection is active
- 2 -
LED
State
Description
(G1-G28)
Blinking
Data transmitted
OFF
Port connection is not active
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
Step 1
Configure the IP addresses of computer and the
device to the same network segment, and the
network
between
them
accessed.
Step 2
Enter device's IP address in the address bar of
the computer browser.
Step 3
Enter device's username and password in the
login window as shown below.
Click "OK" button to login to the WEB interface of
Step 4
the device.
Note:
The
default
IP
address
can
be
mutually
of
the
device
is